Back Button PCM3052ARTFR Datasheet HTML 29Page - Texas Instruments PCM3052ARTFR Datasheet HTML 30Page - Texas Instruments PCM3052ARTFR Datasheet HTML 31Page - Texas Instruments PCM3052ARTFR Datasheet HTML 32Page - Texas Instruments PCM3052ARTFR Datasheet HTML 33Page - Texas Instruments PCM3052ARTFR Datasheet HTML 34Page - Texas Instruments PCM3052ARTFR Datasheet HTML 35Page - Texas Instruments PCM3052ARTFR Datasheet HTML 36Page - Texas Instruments PCM3052ARTFR Datasheet HTML 37Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 33 / 48 page
background image
www.ti.com
TIMING DIAGRAM
SDA
SCL
t(BUF)
t(D-SU)
t(D-HD)
Start
t(LOW)
t(S-HD)
t(SCL-F)
t(SCL-R)
t(HI)
Repeated Start
t(RS-SU)
t(RS-HD)
t(SDA-F)
t(SDA-R)
t(P-SU)
Stop
T0050-01
MODE CONTROL REGISTERS
User-Programmable Mode Controls
PCM3052A
SLES160 – NOVEMBER 2005
PARAMETER
CONDITIONS
MIN
MAX
UNIT
f(SCL)
SCL clock frequency
Standard mode
100
kHz
t(BUF)
Bus free time between STOP and START condition
Standard mode
4.7
µs
t(LOW)
Low period of the SCL clock
Standard mode
4.7
µs
t(HI)
High period of the SCL clock
Standard mode
4
µs
tRS-SU
Setup time for START/repeated START condition
Standard mode
4.7
µs
t(S-HD)
Hold time for START/repeated START condition
Standard mode
4
µs
t(RS-HD)
t(D-SU)
Data setup time
Standard mode
250
ns
t(D-HD)
Data hold time
Standard mode
0
900
ns
t(SCL-R)
Rise time of SCL signal
Standard mode
20 + 0.1 CB
1000
ns
t(SCL-R1)
Rise time of SCL signal after a repeated START condition and after
Standard mode
20 + 0.1 CB
1000
ns
an acknowledge bit
t(SCL-F)
Fall time of SCL signal
Standard mode
20 + 0.1 CB
1000
ns
t(SDA-R)
Rise time of SDA signal
Standard mode
20 + 0.1 CB
1000
ns
t(SDA-F)
Fall time of SDA signal
Standard mode
20 + 0.1 CB
1000
ns
t(P-SU)
Setup time for STOP condition
Standard mode
4
µs
CB
Capacitive load for SDA and SCL line
400
pF
VNH
Noise margin at high level for each connected device (including
Standard mode
0.2 VDD
V
hysteresis)
Figure 55. Control Interface Timing
The PCM3052A has several user programmable functions which are accessed via control registers. The
registers are programmed using the I2C serial control port, which was previously discussed in this data sheet.
Table 4 lists the available mode control functions, along with their reset default conditions and associated register
addresses. The register map is shown in Table 5.
33



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com