Electronic Components Datasheet Search
  English  ▼

X  

TLC1549IP Datasheet(PDF) 6 Page - Texas Instruments

Part # TLC1549IP
Description  10-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL
PDF  20 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

TLC1549IP Datasheet(HTML) 6 Page - Texas Instruments

Back Button TLC1549IP Datasheet HTML 2Page - Texas Instruments TLC1549IP Datasheet HTML 3Page - Texas Instruments TLC1549IP Datasheet HTML 4Page - Texas Instruments TLC1549IP Datasheet HTML 5Page - Texas Instruments TLC1549IP Datasheet HTML 6Page - Texas Instruments TLC1549IP Datasheet HTML 7Page - Texas Instruments TLC1549IP Datasheet HTML 8Page - Texas Instruments TLC1549IP Datasheet HTML 9Page - Texas Instruments TLC1549IP Datasheet HTML 10Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 20 page
background image
TLC1549C, TLC1549I, TLC1549M
10-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL
SLAS059C – DECEMBER 1992 – REVISED MARCH 1995
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SC
Threshold
Detector
NODE 512
REF –
REF+
ST
512
VI
To Output
Latches
1
1
2
4
8
16
128
256
REF+
REF+
REF+
REF+
REF+
REF+
REF –
REF –
REF –
REF –
REF –
REF –
REF –
REF –
ST
ST
ST
ST
ST
ST
ST
ST
Figure 1. Simplified Model of the Successive-Approximation System
chip-select operation
The trailing edge of CS starts all modes of operation, and CS can abort a conversion sequence in any mode.
A high-to-low transition on CS within the specified time during an ongoing cycle aborts the cycle, and the device
returns to the initial state (the contents of the output data register remain at the previous conversion result). Care
should be exercised to prevent CS from being taken low close to completion of conversion because the output
data may be corrupted.
reference voltage inputs
There are two reference inputs used with the TLC1549: REF + and REF –. These voltage values establish the
upper and lower limits of the analog input to produce a full-scale and zero reading respectively. The values of
REF +, REF –, and the analog input should not exceed the positive supply or be lower than GND consistent with
the specified absolute maximum ratings. The digital output is at full scale when the input signal is equal to or
higher than REF + and at zero when the input signal is equal to or lower than REF –.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com