28 / 51 page ![]() DataUpdating DRDY (1)(2) Pin 20t CLK ADS1259 SBAS424D – JUNE 2009 – REVISED AUGUST 2011 www.ti.com SERIAL INTERFACE DATA INPUT (DIN) The SPI-compatible serial interface consists of four DIN is the input data pin and is used with SCLK to signals: CS, SCLK, DIN, and DOUT or three signals, send data to the ADS1259 (opcode commands and in which case CS may be tied low. The interface is register data). The device latches input data on the used to read conversion data, configure registers, falling edge of SCLK. and control the ADS1259 operation. DATA OUTPUT (DOUT) SERIAL COMMUNICATION DOUT is the output data pin and is used with SCLK The ADS1259 communications occur by clocking to read conversion and register data from the commands into the device (on DIN) and reading ADS1259. In addition to providing data output, in register and conversion data (on DOUT). The SCLK RDATAC mode DOUT indicates when data are input is used to clock the data into and out of the ready. Data are ready when DOUT transitions low. In device. CS disables the ADS1259 serial port but this manner, DOUT functions the same as DRDY otherwise does not affect the ADC operation. The (with CS = 0), as shown in Figure 57. When reading communication protocol to the ADS1259 is data, the data are shifted out on the rising edge of half-duplex. That is, data are transmitted to and from SCLK. DOUT is in a 3-state condition when CS is the device one direction at a time. high. Communications to and from the ADS1259 occurs on DATA READY (DRDY) 8-bit boundaries. If an unintentional SCLK transition should occur (such as from a possible noise spike), DRDY is an output that indicates when conversion the ADS1259 serial port may not respond properly. data are available for reading (falling edge active). The port can be reset by one of the following ways: DRDY is asserted on an output pin and also a register bit. To poll the DRDY register bit, set the stop 1. Take CS high and then low to reset the interface read data continuous mode and then read the 2. Hold SCLK low for 216 fCLK cycles to reset the CONFIG2 register. When the DRDY bit is low, data interface can be read. The data read operation must complete 3. Take RESET/PWDN low and back high to overall within 20 fCLK cycles of the next DRDY falling edge. reset the device After power-on or after reset, DRDY defaults high. 4. Cycle the power supplies to overall reset the When reading data in Gate Control mode, DRDY is device reset high on the first SCLK rising edge. If data are not retrieved, DRDY pulses high during the new data CHIP SELECT (CS) update time, as shown in Figure 57. Do not retrieve data during this time as the data are invalid. The chip select (CS) selects the ADS1259 for SPI communication. To select the device, pull CS low. CS In Pulse Control mode, DRDY remains low until a must remain low for the duration of the serial new conversion is started. The previous conversion communication. When CS is taken high, the serial data may be read 20 tCLK prior to the DRDY falling interface is reset, input commands are ignored, and edge. DOUT enters a high-impedance state. If the ADS1259 does not share the serial bus with another device, CS may be tied low. Note that DRDY remains active when CS is high. SERIAL CLOCK (SCLK) The serial clock (SCLK) is a Schmitt-triggered input (1) DOUT functions in the same manner as the DRDY pin if CS is used to clock data into and out of the ADS1259. Even low and in the RDATAC mode. though the input is relatively noise immune, it is (2) The DRDY bit functions in the same manner as the DRDY pin recommended to keep SCLK as clean as possible to (SDATAC mode only). prevent glitches from accidentally shifting the data. If Figure 57. DRDY and DOUT With No Data SCLK is held low for 216 fCLK periods, the serial Retrieval interface resets. After reset the next communication cycle can be started. The timeout can be used to recover communication when the serial interface is interrupted. The SPI timeout is enabled by register bit SPI. When the serial interface is idle, hold SCLK low. 28 Copyright © 2009–2011, Texas Instruments Incorporated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |