Back Button TSC2005IYZLR Datasheet HTML 18Page - Texas Instruments TSC2005IYZLR Datasheet HTML 19Page - Texas Instruments TSC2005IYZLR Datasheet HTML 20Page - Texas Instruments TSC2005IYZLR Datasheet HTML 21Page - Texas Instruments TSC2005IYZLR Datasheet HTML 22Page - Texas Instruments TSC2005IYZLR Datasheet HTML 23Page - Texas Instruments TSC2005IYZLR Datasheet HTML 24Page - Texas Instruments TSC2005IYZLR Datasheet HTML 25Page - Texas Instruments TSC2005IYZLR Datasheet HTML 26Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 46 page
background image
www.ti.com
START A CONVERTER FUNCTION (CONTROL BYTE 1)
ControlByte1Write
CS
(
)
SS
SCLK
SDI
(MOSI)
D7
D3
D5
D4
D2
D6
D0
D1
MSB
LSB
1
1
6
5
4
3
2
8
7
TSC2005
SBAS379C – DECEMBER 2006 – REVISED MARCH 2008
Table 10. Internal Register Map
REGISTER ADDRESS
A3
A2
A1
A0
REGISTER CONTENT
READ/WRITE
0
0
0
0
X measurement result
R
0
0
0
1
Y measurement result
R
0
0
1
0
Z1 measurement result
R
0
0
1
1
Z2 measurement result
R
0
1
0
0
AUX measurement result
R
0
1
0
1
Temp1 measurement result
R
0
1
1
0
Temp2 measurement result
R
0
1
1
1
Status
R
1
0
0
0
AUX high threshold
R/W
1
0
0
1
AUX low threshold
R/W
1
0
1
0
Temp high threshold (apply to both TEMP1 and TEMP2)
R/W
1
0
1
1
Temp low threshold (apply to both TEMP1 and TEMP2)
R/W
1
1
0
0
CFR0
R/W
1
1
0
1
CFR1
R/W
1
1
1
0
CFR2
R/W
1
1
1
1
Converter function select status
R
R/W—Register read and write control. A '1' indicates the contents of the internal register addressed by A3-A0 are
sent to SDO at the next SPI interface clock cycle. A '0' indicates the data following Control Byte 0 on SDI are
written into registers addressed by A3-A0.
Control Byte 1 must begin with D7 = 1, as shown in Figure 28. Control Byte 1 starts the converter function that is
chosen by C3-C0, as shown in Table 7. After sending Control Byte 1, the master does not need to hold CS low,
and can release CS for operating other slave devices that share the same SCLK. After the converter function
completes or stops, the preprocessed data or data set are stored in data registers and can be read by sending
Control Byte 0 with Read Bit and a proper address in A3-A0. For the detailed operating procedures, see the
Operation section.
Figure 28. Interface Timing — Control Byte 1
22
Submit Documentation Feedback
Copyright © 2006–2008, Texas Instruments Incorporated
Product Folder Link(s): TSC2005



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com