| Electronic Components Datasheet Search |
|
ISO7820F Datasheet(PDF) 16 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ISO7820F Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 37 page ![]() 16 ISO7820, ISO7820F SLLSEP0A – JULY 2015 – REVISED MARCH 2016 www.ti.com Product Folder Links: ISO7820 ISO7820F Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated (1) Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier. Table 2. Insulation Characteristics PARAMETER TEST CONDITIONS SPECIFICATION UNIT DW DWW DTI Distance through the insulation Minimum internal gap (internal clearance) 21 21 μm VIOWM Maximum working isolation voltage Time dependent dielectric breakdown (TDDB) test 1500 2000 VRMS 2121 2828 VDC DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 VIOTM Maximum transient isolation voltage VTEST = VIOTM t = 60 sec (qualification) t= 1 sec (100% production) 8000 8000 VPK VIOSM Maximum surge isolation voltage Test method per IEC 60065, 1.2/50 µs waveform, VTEST = 1.6 x VIOSM = 12800 VPK (1) (qualification) 8000 8000 VPK VIORM Maximum repetitive peak isolation voltage 2121 2828 VPK VPR Input-to-output test voltage Method a, After Input/Output safety test subgroup 2/3, VPR = VIORM x 1.2, t = 10 s, Partial discharge < 5 pC 2545 3394 VPK Method a, After environmental tests subgroup 1, VPR = VIORM x 1.6, t = 10 s, Partial Discharge < 5 pC 3394 4525 Method b1,After environmental tests subgroup 1, VPR = VIORM x 1.875, t = 1 s (100% Production test) Partial discharge < 5 pC 3977 5303 RS Isolation resistance VIO = 500 V at TS >109 >109 Ω Pollution degree 2 2 Climatic category 55/125/21 55/125/21 UL 1577 VISO Withstanding isolation voltage VTEST = VISO = 5700 VRMS, t = 60 sec (qualification); VTEST = 1.2 x VISO = 6840 VRMS , t = 1 sec (100% production) 5700 5700 VRMS Table 3. IEC 60664-1 Ratings Table PARAMETER TEST CONDITIONS SPECIFICATION Material group I Overvoltage category / Installation classification DW package Rated mains voltage ≤ 600 VRMS I–IV Rated mains voltage ≤ 1000 VRMS I–III DWW package Rated mains voltage ≤ 1000 VRMS I–IV |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |