4 / 31 page ![]() LM75A SNOS808P – JANUARY 2000 – REVISED DECEMBER 2014 www.ti.com 6.3 Recommended Operating Conditions (1) (2) MIN MAX UNIT Specified Temperature Range (TMIN to TMAX) −55 125 °C Supply Voltage Range (+VS) LM75A 2.7 5.5 V (1) LM75A θJA (thermal resistance, junction-to-ambient) when attached to a printed circuit board with 2 oz. foil similar to the one shown in Thermal Information is summarized in the table below the Operating Ratings table. (2) Reflow temperature profiles are different for lead-free and non-lead-free packages. Soldering process must comply with Reflow Temperature Profile specifications. Refer to www.ti.com/packaging.(2) 6.4 Thermal Information LM75A THERMAL METRIC(1) D DGK UNIT 8 PINS 8 PINS RθJA Junction-to-ambient thermal resistance 200 250 °C/W (1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953. 6.5 Temperature-to-Digital Converter Characteristics Unless otherwise noted, these specifications apply for: +VS = 2.7 to 5.5 Vdc for LM75AIM. TA = TJ = 25°C, unless otherwise noted. PARAMETER TEST CONDITIONS MIN TYP(1) MAX(2) UNIT TA = −25°C to +100°C –2 2 –55°C ≤ TJ ≤ 125°C Accuracy °C TA = −55°C to +125°C –3 3 –55°C ≤ TJ ≤ 125°C Resolution 9 Bits Temperature Conversion Time See(3) 100 ms See(3), –55°C ≤ TJ ≤ 125°C 300 I2C Inactive 0.28 mA I2C Inactive, –55°C ≤ TJ ≤ 125°C 0.5 Quiescent Current LM75A Shutdown Mode, +VS = 3 V 4 μA Shutdown Mode, +VS = 5 V 6 μA O.S. Output Saturation Voltage IOUT = 4 mA, –55°C ≤ TJ ≤ 125°C 0.8 V O.S. Delay See(4), –55°C ≤ TJ ≤ 125°C 1 6 Conversion TOS Default Temperature See(5) 80 °C THYST Default Temperature See(5) 75 °C (1) Typicals are at TA = 25°C and represent most likely parametric norm. (2) Maximum values (limits) are ensured to AOQL (Average Outgoing Quality Level). (3) The conversion-time specification is provided to indicate how often the temperature data is updated. The LM75A can be accessed at any time and reading the Temperature Register will yield result from the last temperature conversion. When the LM75A is accessed, the conversion that is in process will be interrupted and it will be restarted after the end of the communication. Accessing the LM75A continuously without waiting at least one conversion time between communications will prevent the device from updating the Temperature Register with a new temperature conversion result. Consequently, the LM75A should not be accessed continuously with a wait time of less than 300ms. (4) O.S. Delay is user programmable up to 6 “over limit” conversions before O.S. is set to minimize false tripping in noisy environments. (5) Default values set at power up. 4 Submit Documentation Feedback Copyright © 2000–2014, Texas Instruments Incorporated Product Folder Links: LM75A |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |