Back Button TL7700CPWR.A Datasheet HTML 7Page - Texas Instruments TL7700CPWR.A Datasheet HTML 8Page - Texas Instruments TL7700CPWR.A Datasheet HTML 9Page - Texas Instruments TL7700CPWR.A Datasheet HTML 10Page - Texas Instruments TL7700CPWR.A Datasheet HTML 11Page - Texas Instruments TL7700CPWR.A Datasheet HTML 12Page - Texas Instruments TL7700CPWR.A Datasheet HTML 13Page - Texas Instruments TL7700CPWR.A Datasheet HTML 14Page - Texas Instruments TL7700CPWR.A Datasheet HTML 15Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 31 page
background image
tpo
tpo
RESET
Vhys
VCC
1.5 V
T
T
Vs’
VCC
Vs
GND
CT
RESET
RL
R1
R2
Ct
VCC
RESET
GND
SENSE
11
TL7700
www.ti.com
SLVS220G – JULY 1999 – REVISED AUGUST 2016
Product Folder Links: TL7700
Submit Documentation Feedback
Copyright © 1999–2016, Texas Instruments Incorporated
Feature Description (continued)
Figure 18. Setting the Sense Voltage
8.3.2 Sense-Voltage Hysteresis Setting
If the sense voltage (Vs') does not have hysteresis in it, and the voltage on the sensing line contains ripples, the
resetting of TL7700 is unstable. Hysteresis is added to the sense voltage to prevent such problems. As shown in
Figure 19, the hysteresis (Vhys) is added, and the value is determined as:
Vhys = Is × R1
where
•
Is = 2.5 μA typ at TA = 25°C
(2)
At room temperature, Is has variations of 2.5 µA ± 0.5 µA. Therefore, in the circuit shown in Figure 18, Vhys has
variations of (±0.5 × R1) µV. In circuit design, it is necessary to consider the voltage-dividing resistor tolerance
and temperature coefficient in addition to variations in Vs and Vhys.
The sense voltage, Vs', is different from the SENSE terminal input voltage, Vs. Vs normally is 500 mV for triggering.
Figure 19. VCC-RESET Timing Chart



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com