Back Button TLC5930 Datasheet HTML 9Page - Texas Instruments TLC5930 Datasheet HTML 10Page - Texas Instruments TLC5930 Datasheet HTML 11Page - Texas Instruments TLC5930 Datasheet HTML 12Page - Texas Instruments TLC5930 Datasheet HTML 13Page - Texas Instruments TLC5930 Datasheet HTML 14Page - Texas Instruments TLC5930 Datasheet HTML 15Page - Texas Instruments TLC5930 Datasheet HTML 16Page - Texas Instruments TLC5930 Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 41 page
background image
TLC5930
SLLS528 – MARCH 2002
13
www.ti.com
PRINCIPLES OF OPERATION
There are two different methods available as shown in Figure 6 for entering the gray-scale clock when in
light-ON mode. When the gray-scale clock is sequential, lighting-ON by the device is initiated after the HSYNC
packet operation for each device has been completed. When the external clock is used as gray-scale clock, all
the devices can be lighted-ON simultaneously by entering the gray scale clock after the HSYNC packet is
entered for the last device (in this example, just after OVM information reading packet has entered to IC1).
GRAY SCALE
CLOCK
IC1 D/STIN
HSYNC Packet 32 bits
IC1 Constant Current Output
IC2 D/STIN
HSYNC Packet 32 bits
IC2 Constant Current Output
IC15 D/STIN
HSYNC Packet 32 bits
IC15 Constant Current Output
ON
ON
ON
OVM Information Reading Packet 32bits
OVM Information Reading Packet 32bits
IC16 D/STIN
HSYNC Packet 32 bits
IC16 Constant Current Output
ON
Other Packet
Other Packet
GRAY SCALE
CLOCK
IC1 D/STIN
HSYNC Packet 32 bits
IC1 Constant Current Output
IC2 D/STIN
HSYNC Packet 32 bits
IC2 Constant Current Output
IC15 D/STIN
HSYNC Packet 32 bits
IC15 Constant Current Output
ON
ON
ON
OVM Information Reading Packet 32bits
OVM Information Reading Packet 32bits
IC16 D/STIN
HSYNC Packet 32 bits
IC16 Constant Current Output
ON
Other Packet
Other Packet
When Light-ON in a 4 Gray Scale With 16 ICs
When Gray Scale Clock Is Sequential (Including Use of Internally Generated Gray-Scale Clock)
When Gray Scale Clock Is Not Sequential (External Input Only)
Figure 6. Lighting-ON Operation With 16 Devices



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com