Back Button DLPC3479 Datasheet HTML 30Page - Texas Instruments DLPC3479 Datasheet HTML 31Page - Texas Instruments DLPC3479 Datasheet HTML 32Page - Texas Instruments DLPC3479 Datasheet HTML 33Page - Texas Instruments DLPC3479 Datasheet HTML 34Page - Texas Instruments DLPC3479 Datasheet HTML 35Page - Texas Instruments DLPC3479 Datasheet HTML 36Page - Texas Instruments DLPC3479 Datasheet HTML 37Page - Texas Instruments DLPC3479 Datasheet HTML 38Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 45 page
background image
9 Power Supply Recommendations
The following power supplies are all required to operate the DMD:
• VSS
• VBIAS
• VDD
• VDDI
• VOFFSET
• VRESET
The DLPAxxxx device strictly controls the DMD power-up and power-down sequences.
CAUTION
Failure to follow these power supply sequencing requirements may adversley affect device reliability.
See the DMD power supply sequencing requirements in Figure 9-1.
VBIAS, VDD, VDDI, VOFFSET, and VRESET power supplies must be coordinated during power-up
and power-down operations. Failure to meet any of these requirements results in a significant
reduction in the DMD reliability and lifetime. Common ground VSS must also be connected.
9.1 DMD Power Supply Power-Up Procedure
• During the power-up sequence, VDD and VDDI must always start and settle before VOFFSET, VBIAS, and
VRESET voltages are applied to the DMD.
• During the power-up sequence, it is a strict requirement that the voltage difference between VBIAS and
VOFFSET must be within the specified limit shown in Recommended Operating Conditions. Refer to Table
9-1 for the power-up sequence, delay requirements.
• During the power-up sequence, there is no requirement for the relative timing of VRESET with respect to
VBIAS and VOFFSET.
• Power supply slew rates during the power-up sequence are flexible, provided that the transient voltage levels
follow the requirements specified in Absolute Maximum Ratings, in Recommended Operating Conditions, and
in Power Supply Sequencing Requirements.
• During the power-up sequence, LPSDR input pins must not be driven high until after VDD/VDDI have settled
at operating voltages listed in Recommended Operating Conditions.
9.2 DMD Power Supply Power-Down Procedure
• The power-down sequence is the reverse order of the previous power-up sequence. During the power-down
sequence, VDD and VDDI must be supplied until after VBIAS, VRESET, and VOFFSET are discharged to
within 4 V of ground.
• During the power-down sequence, it is a strict requirement that the voltage difference between VBIAS and
VOFFSET must be within the specified limit shown in Recommended Operating Conditions.
• During the power-down sequence, there is no requirement for the relative timing of VRESET with respect to
VBIAS and VOFFSET.
• Power supply slew rates during the power-down sequence, are flexible, provided that the transient
voltage levels follow the requirements specified in Absolute Maximum Ratings, in Recommended Operating
Conditions, and in Power Supply Sequencing Requirements.
• During the power-down sequence, LPSDR input pins must be less than VDD/VDDI specified in
Recommended Operating Conditions.
DLP4710LC
DLPS178C – MAY 2020 – REVISED JULY 2023
www.ti.com
34
Submit Document Feedback
Copyright © 2023 Texas Instruments Incorporated
Product Folder Links: DLP4710LC



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com