Electronic Components Datasheet Search
  English  ▼

X  

MAX4826 Datasheet(PDF) 6 Page - Maxim Integrated Products

Part # MAX4826
Description  50mA/100mA Current-Limit Switches with NO-LOAD Flag in 關DFN
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MAXIM [Maxim Integrated Products]
Direct Link  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

MAX4826 Datasheet(HTML) 6 Page - Maxim Integrated Products

Back Button MAX4826 Datasheet HTML 2Page - Maxim Integrated Products MAX4826 Datasheet HTML 3Page - Maxim Integrated Products MAX4826 Datasheet HTML 4Page - Maxim Integrated Products MAX4826 Datasheet HTML 5Page - Maxim Integrated Products MAX4826 Datasheet HTML 6Page - Maxim Integrated Products MAX4826 Datasheet HTML 7Page - Maxim Integrated Products MAX4826 Datasheet HTML 8Page - Maxim Integrated Products MAX4826 Datasheet HTML 9Page - Maxim Integrated Products MAX4826 Datasheet HTML 10Page - Maxim Integrated Products  
Zoom Inzoom in Zoom Outzoom out
 6 / 10 page
background image
Detailed Description
The MAX4826–MAX4831 are forward-/reverse-current-
limited switches that operate from a +2.3V to +5.5V
input voltage range and guarantee a 50mA and 100mA
minimum current-limit threshold for different options.
The voltage drop across an internal sense resistor is
compared to two reference voltages to indicate a for-
ward- or reverse-current-limit fault. When the load cur-
rent exceeds the preset current limit for greater than
the fault-blanking time, the switch opens.
The MAX4827/MAX4829/MAX4831 have an autoretry
function that turns on the switch again after an internal
retry time expires. If the faulty load condition is still pre-
sent after the blanking time, the switch turns off again
and the cycle is repeated. If the faulty load condition is
not present, the switch remains on.
The MAX4826/MAX4828/MAX4830 do not have the
autoretry option, and the switch remains in latch-off
mode until ON or the input power is cycled from high to
low and then high again.
The undervoltage lockout (UVLO) circuit prevents erro-
neous switch operation when the input voltage goes too
low during startup conditions.
Reverse-Current Protection
The MAX4826–MAX4831 limit the reverse current (VOUT
to VIN) from exceeding the maximum IREV value. The
switch is shut off and FFLG is asserted if the reverse-
current-limit condition persists for more than the blank-
ing time. This feature prevents excessive reverse cur-
rents from flowing through the device.
Switch-On/Off Control
Toggle ON high to enable the current-limited switches.
The switches are continuously on only if VIN exceeds
the UVLO threshold (typically 2V) and there is no fault.
When a forward-/reverse-current fault is present or the
die exceeds the thermal-shutdown temperature of
+150°C, OUT is internally disconnected from IN, and
the supply current decreases to 8µA (latch off). The
switch is now operating in one of its off states. The
switch off state also occurs when driving ON low, thus
reducing the supply current (shutdown) to 0.01µA.
Table 1 illustrates the ON/OFF state of the MAX4826–
MAX4831 current-limit switches.
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
6
_______________________________________________________________________________________
Pin Description
PIN
NAME
FUNCTION
1IN
Input. Bypass IN with a 0.1µF ceramic capacitor to ground.
2
GND
Ground
3
OUT
Switch Output. Bypass OUT with a 0.1µF capacitor to ground
4
FFLG
Current-Limit Fault Output. FFLG is an open-drain output. FFLG goes low when the device stays in
forward- or reverse-current limit for more than the blanking time period. FFLG is high impedance
when a fault is not present or when ON is low.
5
NOLD
No-Load Flag Output. NOLD is an open-drain output. NOLD goes low when a load of less than 10mA
(MAX4826–MAX4829) or 5mA (MAX4830/MAX4831) is delivered to the output. NOLD is high
impedance when a fault is not present or when ON is low.
6ON
Active-High Switch-On Input. Drive ON high to turn the switch on.
ON
FAULT
SWITCH ON/OFF
SUPPLY CURRENT MODE
Low
X
OFF
Shutdown
High
Undervoltage lockout
OFF
Latch off
High
Thermal
OFF immediately (tBLANK period does not apply).
Latch off
OFF after tBLANK period has elapsed.
Latch off
High
Current limit
ON during tBLANK period, OFF during tRETRY period for the
MAX4827/MAX4829/MAX4831. Cycle repeats until fault is
removed.
See the Autoretry section
Table 1. MAX4826–MAX4831 Switch Truth Table



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com