| Electronic Components Datasheet Search |
|
STPM098C Datasheet(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM098C Datasheet(HTML) 20 Page - STMicroelectronics |
|
20 / 110 page ![]() Note: 1. OFF STATE Internal supply and reference voltage/currents levels are degraded or shutdown. The main logic is under reset. All functions are disabled: – Input/output telemetry and monitoring units are disabled; – Control loop is disabled and PWMn outputs are in HIZ; – PMBus™ read/write operations are not available. The device persists in this state if POR_DIG=’0’ (internal signal). 2. WAIT POR_ANA RELEASE STATE Internal supply and reference voltage/currents levels are degraded or shutdown. All functions are disabled: – Input/output telemetry and monitoring units are disabled; – Control loop is disabled and PWMn outputs are in HIZ; – PMBus™ read/write operations are not available. The device persists in this state if POR_ANA = ’0’ (internal signal). 3. NVM DOWNLOAD STATE Internal supply and reference voltage/currents are available possibly exceeding spec parametrical ranges. Main functions are disabled: – Input/output telemetry and monitoring units are disabled; – Control loop is disabled and PWMn outputs are in HIZ; – PMBus™ read/write operations are not available. In this mode a CRC check on NVM data is first performed: – If no CRC error is detected the NVM content is deployed into the main logic register and the next state is BIST STATE; – If a CRC error is detected the related main logic registers are reset to default values (all ‘0’) and the NVM_CRC_FAIL flag is set to ‘1’ and the next state is LOCKUP STATE; – The device persists in this state until the download procedure and CRC check process ends. 4. BIST STATE Internal supply and reference voltage/currents are available and within spec ranges. All functions are disabled: – Input/output telemetry and monitoring units are disabled; – Control loop is disabled and PWMn outputs are in HIZ; – PMBus™ read/write operations are not available. In this mode the following mechanisms are enabled: – ABIST and LBIST: ◦ If it fails the next state is SAFE STATE; ◦ If it does not fail the next state is SAFE STATE; – MBIST: ◦ If it fails the next state is LOCKUP STATE; ◦ If it does not fail the next state is SAFE STATE; The device persists in this state until all checks end. 5. LOCKUP STATE All functions are disabled: – Input/output telemetry and monitoring units are disabled; – Control loop is disabled and PWMn outputs are in HIZ; – PMBus™ read/write operations are not available. System reboot is needed. 6. SAFE STATE MODE Internal supply and reference voltage/currents are available and within spec ranges. Main functions: – Input/output telemetry and monitoring units is partially enabled; – Control loop is disabled and PWMn outputs are in HIZ; STPM098C Functional description DS14440 - Rev 1 page 20/110 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |