| Electronic Components Datasheet Search |
|
INA230AIDGST Datasheet(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
INA230AIDGST Datasheet(HTML) 22 Page - Texas Instruments |
|
22 / 44 page ![]() Table 7-3. Summary of Register Set (continued) POINTER ADDRESS REGISTER NAME FUNCTION POWER-ON RESET TYPE(1) HEX BINARY HEX 04 Current(2) Contains the value of the calculated current flowing through the shunt resistor. 00000000 00000000 0000 R 05 Calibration Sets full-scale range and LSB of current and power measurements. Overall system calibration. 00000000 00000000 0000 R/ W 06 Mask/Enable Alert configuration and conversion ready flag 00000000 00000000 0000 R/ W 07 Alert Limit Contains the limit value to compare to the selected alert function. 00000000 00000000 0000 R/ W FF Die ID Contains unique die identification number. ASCII ASCII R (1) Type: R = read-only, R/ W = read/write. (2) The Current register defaults to '0' because the Calibration register defaults to '0', yielding a zero current and power value until the Calibration register is programmed. 7.6.1 Configuration Register (00h, Read/Write) Table 7-4. Configuration Register (00h, Read/Write) Description BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME RST — — — AVG2 AVG1 AVG0 VBUSCT2 VBUSCT1 VBUSCT0 VSHCT2 VSHCT1 VSHCT0 MODE3 MODE2 MODE1 POR VALUE 0 1 0 0 0 0 0 1 0 0 1 0 0 1 1 1 The Configuration register settings control the operating modes for the INA230. This register controls the conversion time settings for both the shunt and bus voltage measurements, as well as the averaging mode used. The operating mode that controls which signals are selected to be measured is also programmed in the Configuration register. The Configuration register can be read from at any time without impacting or affecting the device settings or a conversion in progress. Writing to the Configuration register halts any conversion in progress until the write sequence is complete, resulting in the start of a new conversion based on the new contents of the Configuration register. This feature prevents any uncertainty in the conditions used for the next completed conversion. RST: Reset Bit Bit 15 Setting this bit to '1' generates a system reset that is the same as a power-on reset; all registers are reset to default values. This bit self-clears. AVG: Averaging Mode Bits 9–11 Sets the number of samples that are collected and averaged together. Table 7-5 summarizes the AVG bit settings and related number of averages for each bit. 7.6.2 AVG Bit Settings [11:9] Table 7-5. AVG Bit Settings [11:9] (1) Description AVG2 (D11) AVG1 (D10) AVG0 (D9) NUMBER OF AVERAGES 0 0 0 1 0 0 1 4 0 1 0 16 0 1 1 64 1 0 0 128 1 0 1 256 INA230 SBOS601B – FEBRUARY 2012 – REVISED JANUARY 2025 www.ti.com 22 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: INA230 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |