22 / 40 page ![]() 7 Registers 7.1 Register Maps The INA226 uses a bank of registers for holding configuration settings, measurement results, minimum/ maximum limits, and status information. Table 7-1 summarizes the device registers; refer to the Functional Block Diagram section for an illustration of the registers. All 16-bit device registers are two 8-bit bytes via the I2C interface. Table 7-1. Register Set Summary POINTER ADDRESS REGISTER NAME FUNCTION POWER-ON RESET TYPE(1) HEX BINARY HEX 00h Configuration Register All-register reset, shunt voltage and bus voltage ADC conversion times and averaging, operating mode. 01000001 00100111 4127 R/ W 01h Shunt Voltage Register Shunt voltage measurement data. 00000000 00000000 0000 R 02h Bus Voltage Register Bus voltage measurement data. 00000000 00000000 0000 R 03h Power Register(2) Contains the value of the calculated power being delivered to the load. 00000000 00000000 0000 R 04h Current Register(2) Contains the value of the calculated current flowing through the shunt resistor. 00000000 00000000 0000 R 05h Calibration Register Sets full-scale range and LSB of current and power measurements. Overall system calibration. 00000000 00000000 0000 R/ W 06h Mask/Enable Register Alert configuration and Conversion Ready flag. 00000000 00000000 0000 R/ W 07h Alert Limit Register Contains the limit value to compare to the selected Alert function. 00000000 00000000 0000 R/ W FEh Manufacturer ID Register Contains unique manufacturer identification number. 0101010001001001 5449 R FFh Die ID Register Contains unique die identification number. 0010001001100000 2260 R (1) Type: R = Read-Only, R/ W = Read/Write. (2) The Current Register (04h) and Power Register (03h) default to '0' because the Calibration register defaults to '0', yielding zero current and power values until the Calibration register is programmed. 7.1.1 Configuration Register (00h) (Read/Write) Table 7-2. Configuration Register (00h) (Read/Write) Descriptions BIT NO. D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME RST — — — AVG2 AVG1 AVG0 VBUSCT2 VBUSCT1 VBUSCT0 VSHCT2 VSHCT1 VSHCT0 MODE3 MODE2 MODE1 POR VALUE 0 1 0 0 0 0 0 1 0 0 1 0 0 1 1 1 The Configuration Register settings control the operating modes for the device. This register controls the conversion time settings for both the shunt and bus voltage measurements as well as the averaging mode used. The operating mode that controls what signals are selected to be measured is also programmed in the Configuration Register . The Configuration Register can be read from at any time without impacting or affecting the device settings or a conversion in progress. Writing to the Configuration Register halts any conversion in progress until the write sequence is completed resulting in a new conversion starting based on the new contents of the Configuration Register (00h). This halt prevents any uncertainty in the conditions used for the next completed conversion. RST: Reset Bit INA226 SBOS547B – JUNE 2011 – REVISED SEPTEMBER 2024 www.ti.com 22 Submit Document Feedback Copyright © 2024 Texas Instruments Incorporated Product Folder Links: INA226 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |