| Electronic Components Datasheet Search |
|
ISOW1044 Datasheet(PDF) 26 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ISOW1044 Datasheet(HTML) 26 Page - Texas Instruments |
|
26 / 48 page ![]() RXD (receiver) TXD (driver) CAN Bus Signal Normal CAN communication TXD fault stuck dominant Example: PCB failure or bad software Driver disabled freeing bus for other nodes Bus would be stuck dominant, blocking communication for the whole network but TXD DTO prevents this and frees the bus for communication after the tTXD_DTO time. tTXD_DTO tTXD_DTO Fault is repaired and transmission capability is restored Communication from other bus nodes Communication from repaired nodes Communication from other bus nodes Communication from repaired nodes Communication from local node Figure 10-6. Example Timing Diagram for TXD DTO Note The minimum dominant TXD time (tTXD_DTO) allowed by the TXD DTO circuit limits the minimum possible transmitted data rate of the device. The CAN protocol allows a maximum of eleven successive dominant bits (on TXD) for the worst case, where five successive dominant bits are followed immediately by an error frame. This, along with the tTXD_DTO minimum, limits the minimum data rate. Calculate the minimum transmitted data rate with Equation 1. Minimum Data Rate = 11 / tTXD_DTO (1) 10.6.4 Power-Up and Power-Down Behavior The ISOW1044 has built-in under-voltage lockout (UVLO) on all supplies (VDD, VIO and VISOOUT) with positive- going and negative-going thresholds and hysteresis. Both the power converter supply (VDD) and Logic supply (VIO) need to be present for the device to work. If either of them is below its UVLO, both the signal path and the power converter are disabled. Assuming VIO is above its UVLO+, when the VDD voltage crosses the positive-going UVLO threshold during power-up, the DC-DC converter initializes and the power converter duty cycle is increased in a controlled manner. This soft-start scheme limits primary peak currents drawn from the VDD supply and charges the VISOOUT output in a controlled manner, avoiding overshoots. CAN BUS is in high impedance state in this duration. When the UVLO positive-going threshold is crossed on the secondary side VISOOUT pin, the feedback channel starts providing feedback to the primary controller. The regulation loop takes over and CAN drive output, Received data output (RXD) and gneral purpose logic channel (OUT) take their respective states defined by the inputs to the device i.e. Standby (STB), Driver data to be transmitted TXD, and general purpose logic input IN respectively. Designers should consider a sufficient time margin (typically 5 ms with 10-µF load capacitance) to allow this power up sequence before any usable system functionality. When either of VDD or VIO is lost, the primary side DC-DC controller turns off when the UVLO lower threshold is reached. The VISOOUT capacitor then discharges depending on the isolation channels and BUS load. 10.6.5 Protection Features The ISOW1044 device has multiple protection features to create a robust system level solution. ISOW1044 SLLSFF7A – MAY 2021 – REVISED DECEMBER 2021 www.ti.com 26 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: ISOW1044 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |