Back Button INA206AIPW Datasheet HTML 19Page - Texas Instruments INA206AIPW Datasheet HTML 20Page - Texas Instruments INA206AIPW Datasheet HTML 21Page - Texas Instruments INA206AIPW Datasheet HTML 22Page - Texas Instruments INA206AIPW Datasheet HTML 23Page - Texas Instruments INA206AIPW Datasheet HTML 24Page - Texas Instruments INA206AIPW Datasheet HTML 25Page - Texas Instruments INA206AIPW Datasheet HTML 26Page - Texas Instruments INA206AIPW Datasheet HTML 27Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 42 page
background image
FILT
5 k
Gain Error%
100
100
5 k
R
æ
ö
W
=
-
´
ç
÷
W +
è
ø
INA206, INA207, INA208
www.ti.com
SBOS360F – JUNE 2006 – REVISED NOVEMBER 2015
Typical Application (continued)
9.2.1 Design Requirements
The device measures current through a resistive shunt with current flowing in one direction. The outputs of the
two comparators are in logic AND connection thus enabling the window comparison. When the INA output
voltage is within the upper and lower limits, the composite comparator output is high. When the INA output
voltage is above the upper limit or below the lower limit, the composite comparator output remains low.
9.2.2 Detailed Design Procedure
9.2.2.1 Selecting RS
The value chosen for the shunt resistor, RS, depends on the application and is a compromise between small-
signal accuracy and maximum permissible voltage loss in the measurement line. High values of RS provide better
accuracy at lower currents by minimizing the effects of offset, while low values of RS minimize voltage loss in the
supply line. For most applications, best performance is attained with an RS value that provides a full-scale shunt
voltage range of 50 mV to 100 mV. Maximum input voltage for accurate measurements is (VS – 0.2) / Gain.
9.2.2.2 Transient Protection
The –16-V to 80-V common-mode range of the INA206, INA207, and INA208 is ideal for withstanding automotive
fault conditions ranging from 12-V battery reversal up to 80-V transients, since no additional protective
components are needed up to those levels. In the event that the INA206, INA207, and INA208 are exposed to
transients on the inputs in excess of their ratings, then external transient absorption with semiconductor transient
absorbers (Zeners or Transzorbs) will be necessary. Use of MOVs or VDRs is not recommended except when
they are used in addition to a semiconductor transient absorber. Select the transient absorber such that it will
never allow the INA206, INA207, and INA208 to be exposed to transients greater than 80 V (that is, allow for
transient absorber tolerance, as well as additional voltage due to transient absorber dynamic impedance).
Despite the use of internal Zener-type ESD protection, the INA206, INA207, and INA208 do not lend themselves
to using external resistors in series with the inputs since the internal gain resistors can vary up to ±30% but are
closely matched. (If gain accuracy is not important, then resistors can be added in series with the INA206,
INA207, and INA208 inputs with two equal resistors on each input.)
9.2.2.3 Input Filtering
An obvious and straightforward location for filtering is at the output of the INA206, INA207, and INA208 series;
however, this location negates the advantage of the low output impedance of the internal buffer. The only other
option for filtering is at the input pins of the INA206, INA207, and INA208, which is complicated by the internal 5
k
Ω + 30% input impedance; this is shown in Figure 42. Using the lowest possible resistor values minimizes both
the initial shift in gain and effects of tolerance. The effect on initial gain is given by Equation 4.
(4)
Total effect on gain error can be calculated by replacing the 5-k
Ω term with 5 kΩ – 30%, (or 3.5 kΩ) or 5 kΩ +
30%, (or 6.5 k
Ω). The tolerance extremes of RFILT can also be inserted into the equation. If a pair of 100 Ω 1%
resistors are used on the inputs, the initial gain error will be 1.96%. Worst-case tolerance conditions will always
occur at the lower excursion of the internal 5-k
Ω resistor (3.5 kΩ), and the higher excursion of RFILT– 2.8% in this
case.
Copyright © 2006–2015, Texas Instruments Incorporated
Submit Documentation Feedback
23
Product Folder Links: INA206 INA207 INA208



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com