| Electronic Components Datasheet Search |
|
LF442QML Datasheet(PDF) 3 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LF442QML Datasheet(HTML) 3 Page - Texas Instruments |
|
3 / 18 page ![]() LF442QML www.ti.com SNOSAO8A – DECEMBER 2010 – REVISED MARCH 2013 Absolute Maximum Ratings (1) Supply Voltage ±18V Differential Input Voltage ±30V Input Voltage Range(2) ±15V Output Short Circuit Duration(3) Continuous Maximum Power Dissipation(4) 900mW TJ max 150°C Still Air 161°C/W θJA Thermal Resistance 500LF/Min Air flow 87°C/W θJC 33°C/W Operating Temperature Range −55°C ≤ TA ≤ 125°C Storage Temperature Range −65°C ≤ TA ≤ 150°C Lead Temperature (Soldering, 10 sec.) 260°C ESD Tolerance(5) 500V (1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. (2) Unless otherwise specified the absolute maximum negative input voltage is equal to the negative power supply voltage. (3) Any of the amplifier outputs can be shorted to ground indefinitely, however, more than one should not be simultaneously shorted as the maximum junction temperature will be exceeded. (4) The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature), θJA (package junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/θJA or the number given in the Absolute Maximum Ratings, whichever is lower. (5) Human Body Model, 100pF discharged through 1.5K Ω Quality Conformance Inspection Table 1. Mil-Std-883, Method 5005 - Group A Subgroup Description Temp (°C) 1 Static tests at +25 2 Static tests at +125 3 Static tests at -55 4 Dynamic tests at +25 5 Dynamic tests at +125 6 Dynamic tests at -55 7 Functional tests at +25 8A Functional tests at +125 8B Functional tests at -55 9 Switching tests at +25 10 Switching tests at +125 11 Switching tests at -55 12 Settling time at +25 13 Settling time at +125 14 Settling time at -55 Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 3 Product Folder Links: LF442QML |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |