Back Button THVD2410V Datasheet HTML 20Page - Texas Instruments THVD2410V Datasheet HTML 21Page - Texas Instruments THVD2410V Datasheet HTML 22Page - Texas Instruments THVD2410V Datasheet HTML 23Page - Texas Instruments THVD2410V Datasheet HTML 24Page - Texas Instruments THVD2410V Datasheet HTML 25Page - Texas Instruments THVD2410V Datasheet HTML 26Page - Texas Instruments THVD2410V Datasheet HTML 27Page - Texas Instruments THVD2410V Datasheet HTML 28Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 41 page
background image
8.2.1.4 Transient Protection
The bus pins of the THVD24xxV transceivers include on-chip ESD protection against ±16-kV HBM and ±15-
kV IEC 61000-4-2 contact discharge for half-duplex devices ±8-kV for full-duplex devices. The International
Electrotechnical Commission (IEC) ESD test is far more severe than the HBM ESD test. The 50% higher charge
capacitance, C(S), and 78% lower discharge resistance, R(D), of the IEC model produce significantly higher
discharge currents than the HBM model. As stated in the IEC 61000-4-2 standard, contact discharge is the
preferred transient protection test method.
R
(C)
R
(D)
C
(S)
High-Voltage
Pulse
Generator
Device
Under
Test
40
35
30
25
20
15
10
5
0
Time (ns)
0
50
100
150
200
250
300
10-kV IEC
10-kV HBM
330 Ω
(1.5 kΩ)
150 pF
(100 pF)
50 M
(1 M)
Figure 8-4. HBM and IEC ESD Models and Currents in Comparison (HBM Values in Parenthesis)
The on-chip implementation of IEC ESD protection significantly increases the robustness of equipment.
Common discharge events occur because of human contact with connectors and cables. Designers may choose
to implement protection against longer duration transients, typically referred to as surge transients.
EFTs are generally caused by relay-contact bounce or the interruption of inductive loads. Surge transients
often result from lightning strikes (direct strike or an indirect strike which induce voltages and currents), or
the switching of power systems, including load changes and short circuit switching. These transients are often
encountered in industrial environments, such as factory automation and power-grid systems.
Figure 8-5 compares the pulse-power of the EFT and surge transients with the power caused by an IEC ESD
transient. The left side of the diagram shows the relative pulse-power for a 0.5-kV surge transient and 4-kV EFT
transient, both of which exceeds the 10-kV ESD transient visible in the lower-left corner. 500-V surge transients
are representative of events that may occur in factory environments in industrial and process automation.
The right side of the diagram shows the pulse power of a 6-kV surge transient, relative to the same 0.5-kV surge
transient. 6-kV surge transients are may occur in power generation and power-grid systems.
22
20
18
16
14
12
10
8
6
4
2
0
Time (µs)
0
5
10
15
20
25
30
35
40
0.5-kV Surge
10-kV ESD
4-kV EFT
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Time (µs)
0
5
10
15
20
25
30
35
40
0.5-kV Surge
6-kV Surge
3.0
2.8
2.6
2.4
Figure 8-5. Power Comparison of ESD, EFT, and Surge Transients
THVD2410V, THVD2412V
THVD2450V, THVD2452V
SLLSFO2B – DECEMBER 2022 – REVISED MARCH 2024
www.ti.com
24
Submit Document Feedback
Copyright © 2024 Texas Instruments Incorporated
Product Folder Links: THVD2410V THVD2412V THVD2450V THVD2452V



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com