36 / 89 page ![]() 6.3.4 Gate Driver Protective Circuits 6.3.4.1 PVDD Supply Undervoltage Warning (PVDD_UVW) If at any time the power supply voltage on the PVDD pin falls below the VPVDD_UVW threshold for longer than the tPVDD_UVW_DG time, the DRV8334 detects a PVDD undervoltage warning event. After detecting the undervoltage condition, the device asserts a warning in accordance with the WARN_MODE bit. The VPVDD_UVW threshold is adjustable through the SPI register bit PVDD_UVW_LVL. 6.3.4.2 PVDD Supply Undervoltage Lockout (PVDD_UV) If at any time the power supply voltage on the PVDD pin falls below the VPVDD_UV threshold for longer than the tPVDD_UV_DG time, the DRV8334 detects a PVDD undervoltage event. After detecting the undervoltage condition, the gate driver disabled, charge pump disabled and nFAULT pin is driven low. After PVDD_UV condition is cleared, the fault state remains latched and can be cleared through an SPI command. 6.3.4.3 PVDD Supply Overvoltage Fault (PVDD_OV) If at any time the power supply voltage on the PVDD pin exceeds the VPVDD_OV threshold for longer than the tPVDD_OV_DG time, the DRV8334 detects a PVDD overvoltage event. After detecting the overvoltage condition, the gate driver is disabled, charge pump is disabled, and nFAULT pin is driven low. After PVDD_OV condition is cleared, the fault state remains latched and can be cleared through an SPI command. The PVDD_OV threshold is adjustable through the SPI register field PVDD_OV_LVL. The PVDD OV threshold is adjustable through the SPI register field PVDD_OV_LVL, with settings available for 28V, 33V, or 50V. 6.3.4.4 GVDD Undervoltage Lockout (GVDD_UV) If at any time the voltage on the GVDD pin falls lower than the VGVDD_UV threshold voltage for longer than the tGVDD_UV_DG time, the device detects a GVDD undervoltage event. After detecting the GVDD_UV undervoltage event, the gate driver is disabled, VCP charge pump is disabled and nFAULT pin is driven low if the GVDD_UV_MODE bit is 1b. After GVDD_UV condition is cleared, the fault state remains latched and can be cleared through an SPI command. 6.3.4.5 GVDD Overvoltage Fault (GVDD_OV) If at any time the power supply voltage on the GVDD pin exceeds the VGVDD_OV threshold for longer than the tGVDD_OV_DG time, the DRV8334 detects a GVDD overvoltage event. After detecting the overvoltage condition, the gate driver is disabled, charge pump is disabled, and nFAULT pin is driven low. After PVDD_OV condition is cleared, the fault state remains latched and can be cleared through an SPI command. 6.3.4.6 BST Undervoltage Lockout (BST_UV) If at any time the voltage across BTSx and SHx pins falls lower than the VBST_UV threshold voltage for longer than the tBST_UV_DG time, the device detects a BST undervoltage event. After detecting the BST_UV undervoltage event, the high-side gate driver is disabled and nFAULT pin is driven low if the BST_UV_MODE register bit is 1b. The low-side gate driver remains active during BST_UV event. After the BST_UV condition is cleared, the fault state remains latched if BST_UV_LATCH register bit is 1b, and the flag can be cleared through an SPI command. 6.3.4.7 BST Overvoltage Fault (BST_OV) If at any time the power supply voltage on one of the BSTx pins exceeds the VBST_OV threshold for longer than the tBST_OV_DG time, the DRV8334 detects a BST overvoltage event. After detecting the overvoltage condition, the gate driver is disabled, charge pump is disabled, and nFAULT pin is driven low. After BST_OV condition is cleared, the fault state remains latched and can be cleared through an SPI command. 6.3.4.8 VCP Undervoltage Fault (CP_OV) If at any time the voltage between the VCP and VDRAIN pins falls below the VCP_UV threshold for longer than the tCP_UV_DG time, the DRV8334 detects a VCP undervoltage event. After detecting the undervoltage condition, the gate driver is disabled, charge pump is disabled, and nFAULT pin is driven low. After the VCP_UV condition is cleared, the fault state remains latched and can be cleared through an SPI command. DRV8334 SLVSHC7B – DECEMBER 2023 – REVISED SEPTEMBER 2025 www.ti.com 36 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: DRV8334 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |