Back Button TPS2480PW Datasheet HTML 38Page - Texas Instruments TPS2480PW Datasheet HTML 39Page - Texas Instruments TPS2480PW Datasheet HTML 40Page - Texas Instruments TPS2480PW Datasheet HTML 41Page - Texas Instruments TPS2480PW Datasheet HTML 42Page - Texas Instruments TPS2480PW Datasheet HTML 43Page - Texas Instruments TPS2480PW Datasheet HTML 44Page - Texas Instruments TPS2480PW Datasheet HTML 45Page - Texas Instruments TPS2480PW Datasheet HTML 46Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 42 / 60 page
background image
Max_Current=Current_LSB
32767
´
Max_Current=62.2573
Max_ShuntVoltage=Max_Current_Before_Overflow
R
´
SHUNT
Max_ShuntVoltage=0.0622573
MaximumPower=Max_Current_Before_Overflow
V
´
BUS_MAX
MaximumPower=1992
Corrected_Full_Scale_Cal=trunc
Cal
MeasShuntCurrent
TPS2480/81_Current
´
Corrected_Full_Scale_Cal=21422
TPS2480
TPS2481
SLUS939B – APRIL 2010 – REVISED DECEMBER 2010
www.ti.com
7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 44 and
Equation 45. Note that both Equation 44 and Equation 45 involve an If - then condition.
(44)
If Max_Current
≥ Max Possible_I then
Max_Current_Before_Overflow = MaxPossible_I
Else
Max_Current_Before_Overflow = Max_Current
End If
(Note that Max_Current is less than MaxPossible_I in this example.)
Max_Current_Before_Overflow = 62.2573 (Note: This result is displayed by software as seen in Figure 27.)
(45)
If Max_ShuntVoltage
≥ VSHUNT_MAX
Max_ShuntVoltage_Before_Overflow = VSHUNT_MAX
Else
Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage
End If
(Note that Max_ShuntVoltage is less than VSHUNT_MAX in this example.)
Max_ShuntVoltage_Before_Overflow = 0.0622573 (Note: This result is displayed by software as seen in
Figure 27.)
8. Compute the maximum power with equation 8.
(46)
9. (Optional second calibration step.) Compute the corrected full-scale calibration value based on measured
current.
TPS2480/81_Current = 25.2472
MeaShuntCurrent = 25.09
(47)
42
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): TPS2480 TPS2481



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com