| Electronic Components Datasheet Search |
|
PD70100 Datasheet(PDF) 9 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
PD70100 Datasheet(HTML) 9 Page - Microsemi Corporation |
|
9 / 19 page ![]() IEEE 802.3af/at PD Front End IC Microsemi Proprietary and Confidential. PD70100/PD70200 Datasheet Revision 3.0 6 Internal logic monitors V to VPN voltage and keeps the MOSFET in a high impedance state until V to PP IN PP VPN voltage reaches turn-on threshold of 36 V to 42 V. Once V to VPN voltage exceeds this IN PP IN threshold, the MOSFET is switched into one of two modes. The mode into which the MOSFET is switched is determined by the voltage developed across the MOSFET, or put another way, the VPN to VPN differential voltage. Two modes are defined below: OUT IN Table 1 • Isolation Switch Modes VPN to VPN OUT IN Mode Description > 0.7 V Soft Start Mode Limits VPN current to 240 mA (typical) OUT ≤ 0.7 V Normal Operating Mode Limits VPN current to 1.8 A (typical) OUT By controlling the MOSFET current based on VPN to VPN voltage, inrush currents generated by fully OUT IN discharged bulk capacitors can be limited. This method limits current to a maximum of 350 mA, compliant with IEEE 802.3af/at specification. Soft Start current limiting is required to reduce occurrences of voltage sag at the PD input during device power-up. A comparison is shown in the figure below. Once bulk capacitance has charged up to a point where VPN to VPN differential voltage is less than OUT IN 0.7 V, the isolation MOSFET is switched into normal operating mode with MOSFET current limit set at 1.8 A (typical), to provide over-current protection. PD70100 and PD70200 ICs are different in their respective isolation MOSFET’s continuous current handling capability: PD70100: 450 mA (max.) PD70200: 1123 mA (max.) An adequate heat sink for the PD70100/PD70200 IC’s exposed pad must be provided to achieve these current levels without damaging the IC. A large, heavy copper fill area and/or a heavy ground plane with Thermal Vias is recommended. Electrically the exposed pad ground plane should be connected to VPNIN. Internal logic monitoring V to VPN will place the isolation switch MOSFET in a high impedance state if PP IN voltage between V and VPN drops below 31 V to 34 V. PP IN 3.1.5 Over-Current Protection Over-current protection is provided on the PD70100/PD70200 IC using the Isolation MOSFET Switch, which limits the VPN current to 1.8 A during normal operation. See previous description of Soft Start. OUT |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |