| Electronic Components Datasheet Search |
|
LM4859 Datasheet(PDF) 23 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM4859 Datasheet(HTML) 23 Page - National Semiconductor (TI) |
|
23 / 29 page ![]() Application Information (Continued) shown in the Demonstration Board Layout section. Further detailed and specific information concerning PCB layout and fabrication and mounting an SP (LLP) is found in National Semiconductor’s AN1187. PCB LAYOUT AND SUPPLY REGULATION CONSIDERATIONS FOR DRIVING 3 Ω AND 4Ω LOADS Power dissipated by a load is a function of the voltage swing across the load and the load’s impedance. As load imped- ance decreases, load dissipation becomes increasingly de- pendent on the interconnect (PCB trace and wire) resistance between the amplifier output pins and the load’s connec- tions. Residual trace resistance causes a voltage drop, which results in power dissipated in the trace and not in the load as desired. For example, 0.1 Ω trace resistance reduces the output power dissipated by a 4 Ω load from 1.6W to 1.5W. The problem of decreased load dissipation is exacerbated as load impedance decreases. Therefore, to maintain the highest load dissipation and widest output voltage swing, PCB traces that connect the output pins to a load must be as wide as possible. Poor power supply regulation adversely affects maximum output power. A poorly regulated supply’s output voltage decreases with increasing load current. Reduced supply voltage causes decreased headroom, output signal clipping, and reduced output power. Even with tightly regulated sup- plies, trace resistance creates the same effects as poor supply regulation. Therefore, making the power supply traces as wide as possible helps maintain full output voltage swing. BRIDGE CONFIGURATION EXPLANATION The LM4859 consists of two sets of bridged-tied amplifier pairs that drive the left loudspeaker (LLS) and the right loudspeaker (RLS). For this discussion, only the LLS bridge- tied amplifier pair will be referred to. The LM4859 drives a load, such as a speaker, connected between outputs, LLS+ and LLS-. In the LLS amplifier block, the output of the amplifier that drives LLS- serves as the input to the unity gain inverting amplifier that drives LLS+. This results in both amplifiers producing signals identical in magnitude, but 180˚ out of phase. Taking advantage of this phase difference, a load is placed between LLS- and LLS+ and driven differentially (commonly referred to as ’bridge mode’). This results in a differential or BTL gain of: A VD = 2(Rf /Ri)=2 (2) Both the feedback resistor, R f, and the input resistor, Ri, are internally set. Bridge mode amplifiers are different from single-ended am- plifiers that drive loads connected between a single amplifi- er’s output and ground. For a given supply voltage, bridge mode has a distinct advantage over the single-ended con- figuration: its differential output doubles the voltage swing across the load. Theoretically, this produces four times the output power when compared to a single-ended amplifier under the same conditions. This increase in attainable output power assumes that the amplifier is not current limited and that the output signal is not clipped. Another advantage of the differential bridge output is no net DC voltage across the load. This is accomplished by biasing LLS- and LLS+ outputs at half-supply. This eliminates the coupling capacitor that single supply, single-ended amplifiers require. Eliminating an output coupling capacitor in a typical single-ended configuration forces a single-supply amplifier’s half-supply bias voltage across the load. This increases internal IC power dissipation and may permanently damage loads such as speakers. POWER DISSIPATION Power dissipation is a major concern when designing a successful single-ended or bridged amplifier. A direct consequence of the increased power delivered to the load by a bridge amplifier is higher internal power dissi- pation. The LM4859 has 2 sets of bridged-tied amplifier pairs driving LLS and RLS. The maximum internal power dissipa- tion operating in the bridge mode is twice that of a single- ended amplifier. From Equation (3) and (4), assuming a 5V power supply and an 8 Ω load, the maximum power dissipa- tion for LLS and RLS is 634mW per channel. P DMAX-LLS = 4(VDD) 2 / (2 π2 R L): Bridged (3) P DMAX-RLS = 4(VDD) 2 / (2 π2 R L): Bridged (4) The LM4859 also has a pair of single-ended amplifiers driv- ing LHP and RHP. The maximum internal power dissipation for ROUT and LOUT is given by equation (5) and (6). From Equations (5) and (6), assuming a 5V power supply and a 32 Ω load, the maximum power dissipation for LOUT and ROUT is 40mW per channel. P DMAX-LHP =(VDD) 2 /(2 π2 R L): Single-ended (5) P DMAX-RHP =(VDD) 2 /(2 π2 R L): Single-ended (6) The maximum internal power dissipation of the LM4859 occurs during output modes 3, 8, and 13 when both loud- speaker and headphone amplifiers are simultaneously on; and is given by Equation (7). P DMAX-TOTAL = P DMAX-LLS +PDMAX-RLS +PDMAX-LHP +PDMAX-RHP (7) The maximum power dissipation point given by Equation (7) must not exceed the power dissipation given by Equation (8): P DMAX’= (TJMAX -TA)/ θ JA (8) The LM4859’s T JMAX = 150˚C. In the SP package, the LM4859’s θ JA is 42˚C/W. At any given ambient temperature T A, use Equation (8) to find the maximum internal power dissipation supported by the IC packaging. Rearranging Equation (8) and substituting P DMAX-TOTAL for PDMAX’ results in Equation (9). This equation gives the maximum ambient temperature that still allows maximum stereo power dissipa- tion without violating the LM4859’s maximum junction tem- perature. T A =TJMAX -PDMAX-TOTAL θ JA (9) www.national.com 23 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |