| Electronic Components Datasheet Search |
|
PDSP16256A Datasheet(PDF) 12 Page - Mitel Networks Corporation |
|
|
|||||||||||||||||||||||||||||
PDSP16256A Datasheet(HTML) 12 Page - Mitel Networks Corporation |
|
12 / 24 page ![]() PDSP16256 12 system contains a microprocessor they can be individually transferred from a remote master under software control. In any mode the system clock must be present and stable during the transfer, and the addressing scheme is such that the least significant address specifies the coefficient applied to the first multiplier seen by incoming data. The addresses used during the load operation are those illustrated in Fig. 15. The Control Register is loaded when CCS is high. In byte mode address A0 is used to select the portion of control register loaded, otherwise the address bits are redundant. When an EPROM is used to provide coefficients, this redundancy causes the number of locations needed for any device to be double that for the coefficients alone. AUTO EPROM LOAD When EPROM is tied low, the PDSP16256 assumes the role of a master device in the system and controls the loading of coefficients from an external EPROM, see Fig.15. A load sequence commences when the RES input goes high, and will continue until every coefficient has been loaded. BUSY goes high to indicate that a load sequence is occurring and the filter output is invalid. The device will not commence a filter operation until the FEN edge is received after BUSY has gone low. This requirement can be avoided if FRUN is tied high. The address bus pins become outputs on the Master device, and produce a new address every four system clock periods. This four clock interval, minus output delays and the data set up time, defines the available EPROM access time. The coefficients are always loaded as bytes. The state of the BYTE pin on the master device is ignored. This ar- rangement also allows the eight most significant coefficient bus pins (C15:8) to be used for other purposes as described later. Since the 16-bit coefficients are loaded in two bytes the A0 pin specifies the required byte. The maximum number of stored coefficients is 128, eight address outputs are therefore pro- vided for the EPROM. These eight outputs from the Master must also drive the address inputs on the slave devices. LOAD LAST MASTER COEFFICIENT SCLK A7:0 CCS C15:12 FE FF 00 01 00 01 FE FF 00 01 00 01 0000 0001 0001 0010 LOAD SLAVE 1 CONTROL REGISTER LOAD SLAVE 1 COEFFICIENTS LOAD LAST SLAVE 1 COEFFICIENT LOAD SLAVE 2 CONTROL REGISTER LOAD SLAVE 2 COEFFICIENTS Fig. 15a EPROM load sequence Fig. 15b EPROM load sequence for a cascaded system SCLK 00 01 00 LOAD MASTER CONTROL REGISTER LOAD LAST COEFFICIENT A7:0 00 01 LOAD FIRST COEFFICIENT VALID ADDR VALID ADDR CCS RES BUSY Fig. 15 EPROM load sequence timing diagrams |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |