40 / 44 page ![]() M50LPW080 40/44 Figure 20. Chip Erase Flowchart and Pseudo Code (A/A Mux Interface Only) Note: If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. Write 80h AI04195 Start Write 10h Read Status Register YES NO b7 = 1 YES NO b3 = 0 NO b4, b5 = 0 VPP Invalid Error (1) Command Sequence Error (1) Chip Erase command: – write 80h – write 10h (memory enters read Status Register after the Chip Erase command) do: – read Status Register while b7 = 1 If b3 = 1, VPP invalid error: – error handler If b4, b5 = 1, Command sequence error: – error handler YES NO b5 = 0 Erase Error (1) If b5 = 1, Erase error: – error handler End YES |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|