17 / 27 page ![]() Radiometrix Ltd, FRPC2 page 17 In some modes the RXR output from the FRPC2 is driven low to indicate 'pass' or 'OK'. An LED + 1kΩ from RXR to 5V is recommended. Mode Name Function 0 RX-ON PREAMBLE DETECTOR ON (RXR RED LED = preamble detected) 1 RX-PULSE 10ms ON : 10ms OFF, PREAMBLE DETECTOR ON RXR LED 2 TX-ON-PRE Preamble Modulation - send continuous preamble 3 TX-ON-SQ 100Hz SQUARE WAVE MOD - TX testing on spec. Analyser 4 TX-ON-255 random 160kbit/s data for EYE DIAGRAM tests, sync's on RXR 5 TX-PULSE PREAMBLE BURSTS (EE 01 SETTING): 10ms OFF, RX lock in tests 6 ECHO TRANSPONDER MODE, re-transmit any valid packets received 7 RADAR Send ASCII TEST PACKET "RADIOMETRIX" and listen for echo Modes 6 & 7 are particularly useful for software debugging and range testing. D3 D2 D1 D0 Mode 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 figure 15: stand-alone diagnostic mode |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|