| Electronic Components Datasheet Search |
|
C139 Datasheet(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C139 Datasheet(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 1090 Portable Process Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2b 06/22 Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Temperature Measure accuracy Simulate accuracy Thermocouple type Temp range °C Accuracy °C Thermocouple type Temp range °C Accuracy °C J –200 to 580 0.7 J –210 to 150 0.15 150 to 1200 0.3 K –200 to -150 2.5 K –270 to 190 0.5 –150 to 750 0.5 190 to 1250 0.4 T –200 to 0 1.5 T –200 to 150 0.4 0 to 400 0.4 150 to 400 0.5 R 50 to 400 3.0 R –50 to 800 0.8 400 to 1750 1.5 800 to 1750 2.0 S –50 to 100 3.0 S –50 to 850 0.9 100 to 1750 1.5 850 to 1750 2.0 B 110 to 1000 3.5 B 100 to 1200 2.0 1000 to 1800 1.5 1200 to 1800 3.0 N –100 to 890 0.6 N –270 to 260 0.5 260 to 1300 1.0 E –50 to 400 0.4 E –50 to 1000 0.3 Resolution: 0.1 °C or °F Resolution: 0.1 °C or °F An additional correction representing the equivalent 1 μV should be allowed for stray thermal emf effects. PT100 Pt100 measure Pt100 simulation Range Accuracy Resolution Set temperature points (°C) Accuracy –200 to 700 °C, 2 wire. 0.2 % of resistance value (typically 0.7 °C) 0.2 °C or °F –100, –50, –20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 0.1 % of resistance value (typically 0.5 °C) Voltage Millivolt measure Millivolt source Range Resolution Accuracy Input resistance Range Resolution Accuracy Output resistance 0 to 30 mV 10 μV 0.05 % FS ± 1 digit 100 kΩ 0 to 8 mV 0.5 μV ± 4 μV 10 Ω 8 to 80 mV 5 μV 0.02 % FS 10 Ω Current Milliamp measure Milliamp source Range Resolution Accuracy Input resistance Range Resolution Accuracy Max load (24 V drive) 0 to 60 mA 20 μA 0.05 % FS ± 1 digit 0.5 Ω 0 to 8 mA 0.5 μA ± 10 μA 300 Ω / 80 mA 480 Ω / 50 mA 1.2 kΩ / 20 mA 8 to 80 mA 5 μA 0.02 % FS Inching............................................................ Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10, or 100 μV/μA for voltage/current. ......................................................................... The lowest of these represents the highest setting resolution and provides the most precise control of the output. 24 V Process loop drive mode..................... A process loop can be driven at 24 V and up to 60 mA by selecting the ‘Milliamp Source’ mode and setting ......................................................................... it at 60 mA (or a lower level if required). Memory recall and step functions ............... 10 memory locations for non-volatile storage of values. Manual & AutoStep, rate adjustable from 1 to 10 sec/step. General Specifications Cold junction compensation ........................ Accuracy: 0.2 °C. Resolution: 0.1 °C. Operating temperature ................................. 10 to 40 °C (15 to 105 °F). Connections................................................... Industry standard 4 mm screw terminals. Power.............................................................. A Ni-MH rechargeable battery pack gives approx. 60 hours continuous use. The mains recharger supplied ...................................................................... gives full recharge in 11 hours. To conserve battery life a user inactivity power-down feature is included. Dimensions / weight...................................... H 235 x W 150 x D 75 mm, weight 1.2 kg. Optional extras .............................................. Calibration certificates: Traceable (Factory) and Accredited (ISO 17025). Ordering Information 1090.............................................................. Portable Process Calibrator C177................................................................ Traceable calibration certificate (Factory) C139................................................................ Accredited calibration certificate (ISO 17025) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |