21 / 53 page ![]() 21/53 M58LW064A, M58LW064B Clear Status Register Instruction (CLRS). The Clear Status Register Instruction is given with the command 50h at any address location. It is a reset instruction that resets DQ5, DQ4 and DQ1 in the Status Register to ’0’. If an operation such as Block Erase, Write to Buff- er and Program Block Protect or Block Unprotect has failed, the P/E.C. will set DQ5, DQ4 or DQ1 to ’1’ depending on the failure detected (see Table 12, Status Register Definition). The Clear Status Register Instruction must be given before restart- ing any corrective Erase/Program Instruction. The CLRS Instruction should be given also after an Erase or Program Suspend Instruction failure or before a Resume Instruction if the previous in- struction has been detected to have failed. It is also a software reset solution that may allow the execution of several operations such as cumulat- ed Erase or Block Protect operations of multiple blocks. The Clear Status Register instruction is valid when the P/E.C. is inactive or the device is in a suspend mode and it is also valid independent of the voltage VIH or VHH applied on the RP input. Write to Buffer and Program Instruction (WB- PR). The Write to Buffer and Program Instruction is used to program the memory array. Up to 16 Words or 8 Double-Words can be loaded into the Write Buffer and programmed into the device. The Write to buffer and Program Instruction is com- posed of three successive steps. The first step is to give the Write to Buffer and Program command, E8h with the selected memory Block Address where the program operation should occur. The Status Register DQ7 bit then indicates the ”buffer available” status. If the write buffer is not available (indicated by DQ7 = 0) then the software can ei- ther continue monitoring DQ7 until it transitions to 1, or else re-try later by reloading first the WBPR command, E8h, and then again monitoring the val- ue of DQ7. Once the ”write buffer available” condition is valid (indicated by DQ7 = 1), the second step is to write the block address again, along with the value N, where N+1 is the number of Words (x16 organisa- tion) or Double-Words (x32 organisation) to be programmed. In the third step, a sequence of N+1 write cycles loads the addresses and data to the write buffer (see boundary constraints below). The addresses must lie between the starting address and the starting address + (N+1). The array must be programmed in 4 Word or 2 Double-Word blocks, which must be aligned with an A2 = A1 = 0 starting address (or A2 = 0 for x32 organisation). Invalid data will be flagged and the operation will abort with the status register bits DQ4 and DQ5 set to 1. The Confirm Command, D0h (the same as Erase/ Program Resume PER Instruction) needs to be given immediately after the completion of the Write to Buffer and Program Instruction. It represents the last (that is the N+2) write operation. The P/E.C. is enabled only if the whole previous sequence is fully respected. Otherwise an Invalid Command/Sequence error will be generated with the Status Register DQ5 and DQ4 set to ’1’. For additional Write to Buffer and Program operations, after the initial input command the software can check the availability of the write buffer by check- ing DQ7 status from the Status Register. If an error appears during a program sequence, the device will stop its operation and DQ4 of the Status Register will be set to ’1’ to indicate a pro- gram failure. DQ5 will indicate if an error has been detected during a Block Erase operation. If these bits, DQ4 or DQ5 are set to ’1’, the Write to Buffer and Program input command is not accepted by the device until the status register has been cleared. Additionally, if the Block is protected and VIH <RP < VHH instead of RP = VHH, the Write to Buffer and Program Instruction will not be accept- ed by the device, and DQ4 and DQ1 of the status register will be set to ’1’. Block Protect Instruction (BP). The Block Pro- tect Instruction BP uses a two-cycle write se- quence. The first write cycle gives the command 60h at any address location. The second write cy- cle gives the block address memory location to be protected and the command 01h. Block protection can be cleared with the BU In- struction, which unprotects all blocks. Alternative- ly, temporary unprotect can be achieved by raising the RP input to VHH and holding it at that level throughout the Block Erase or Write to Buffer and Program operations. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |