| Electronic Components Datasheet Search |
|
8030 Datasheet(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
8030 Datasheet(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 8030 Automatic Pressure Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications Pressure ranges .........................................................–1 to 100 bar (1500 psi). Configured based on customer range requirement. Internal sensors..........................................................3 in total plus 1 barometric reference. Pressure types............................................................Gauge, compound, absolute and differential. Accuracy (per sensor) ...............................................0.01 % FS ......................................................................................0.03 % FS for low range and differential sensors (30 mbar to 300 mbar). Precision .....................................................................< 0.005 % FS. Barometric reference option .....................................Enables user to switch from gauge to absolute pressure. ......................................................................................Measuring range: 800 to 1,200 mbar absolute. Accuracy: 0.01 % RDG. Pressure units.............................................................20 selectable and 1 programmable. Control stability...........................................................< 0.005 % FS of the active sensor. Control time ................................................................< 10 s. Pressure ports ............................................................Minimess type with hoses supplied. BSP and NPT available. Pressure media...........................................................Clean, dry, non-corrosive, non-combustible and non-oxidising gases. Overpressure protection ...........................................150 % of the largest pressure range. Screen .........................................................................7 ” TFT colour touch-screen (4 wire resistive). Resolution ...................................................................up to 6 digits (user selectable). Response time............................................................approx. 10 ms. Warm-up time .............................................................approx. 10 minutes. Communication interface ..........................................RS-232 and ethernet. Power supply ..............................................................100 to 230 V AC, 50/60 Hz. Supply port pressure .................................................Maximum 105 to 110 % FS. Test port pressure ......................................................Maximum 105 % FS. Operating temperature ..............................................10 to 40 °C (50 to 104 °F). Storage temperature..................................................0 to 70 °C (32 to 158 °F). Air humidity.................................................................0 to 95 % (relative humidity without moisture condensation). Compensated temperature range ............................15 to 35 °C (59 to 95 °F). Dimensions/Weight ....................................................W 235 x H 132 x D 375 mm / Weight: approx 12 kg depending on sensors ordered. Additional 8030 versions ...........................................0 to 140 bar (2000 psi), 0 to 200 bar (3000 psi), 0 to 230 bar (3350 psi). ......................................................................................High pressure models can have up to 2 internal sensors plus 1 barometric reference. ......................................................................................Hydraulic version up to 1000 bar (see 8030-H data sheet). Supplied with ..............................................................Contamination trap, 2 port manifold, hoses, fittings, power lead, user manuals. Ordering Information 8030..........................................................................Automatic Pressure Calibrator/Controller ......................................................................................Can be configured with up to 3 sensors and a barometric reference. 8030BARO....................................................................Barometric reference option for 8030 7165..............................................................................8030 compressor pump (17, 35, 50 and 70 bar versions available, range based on 8030 ordered) 7149..............................................................................Electical vacuum pump 7161P ..............................................................................Quad port pneumatic manifold (for use up to 200 bar) ECFLA ..........................................................................EasyCal Calibration Software (full user licence, accompanying calibrator discounted price) Calibration Certificates.................................................Traceable calibration certificate (Factory) and Accredited calibration certificate (ISO 17025) Additional options include instrument UUT stands, fittings, manifolds, pressure adaptor kits, hoses. Available upon request. v3a 09/21 Due to continuous development Time Electronics reserves the right to change specifications without prior notice. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |