Electronic Components Datasheet Search
  English  ▼

X  

7090 Datasheet(PDF) 1 Page - Time Electronics Ltd.

Part # 7090
Description  7016 Regulated Low Pressure Calibrator
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TIME-ELECTRONICS [Time Electronics Ltd.]
Direct Link  https://www.timeelectronics.com/
Logo TIME-ELECTRONICS - Time Electronics Ltd.

7090 Datasheet(HTML) 1 Page - Time Electronics Ltd.

  7090 Datasheet HTML 1Page - Time Electronics Ltd. 7090 Datasheet HTML 2Page - Time Electronics Ltd.  
Zoom Inzoom in Zoom Outzoom out
 1 / 2 page
background image
Time Electronics
7016 Regulated Low Pressure Calibrator
Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com
Description
The 7016 is a fully integrated pressure test and calibration system. It is suitable for field
and laboratory calibration work of both regulated low pressure and electrical process
loop signals. The instrument is available in pressure or vacuum regulated configuration,
with the range specified on ordering. There are five available versions according to
required output range, either vacuum, 0.2, 2, 5, or 10 bar.
The 7016 combines high accuracy with simple operation, and is the popular choice for
test engineers performing pressure calibration applications under 10 bar. It is an easy to
use instrument suitable for calibration and maintenance of pressure gauges, sensors,
transmitters, transducers, indicators, switches, and more.
Features include a 4.5 digit LCD display, 4 pressure units plus mA, zeroing switch, and
regulator for output control. Basic pressure accuracy is 0.04 % of full scale and line
pressure is supplied via an input quick release port fitted on the side of the unit.
For process signal calibration the loop signal is displayed on the LCD display to 0.05 %
accuracy. Loop drive supply (24 V or 36 V) is also provided. Both pressure and loop signal
can be displayed at the same time to speed up the calibration of pressure transmitters.
Additionally a continuity function is available for testing for open circuit loops.
Power is via internal rechargeable cells (24 hours typical use) with a built-in mains
charger. The unit can be powered directly from the mains if required. The 7016 is housed
in an impact resistant safety case that provides protection and increased durability. All
pressure connections are on the side of the case. The instrument is supplied with a
pressure hose, electrical test lead, 2 electrical probes and 2 crocodile clips.
Options
For the 7016, input pressure for regulation can be provided by a compressor or gas
cylinder. When used as a measuring instrument in the field, pressure can be generated
by pumps like the 7090 pneumatic hand pump (vacuum to 40 bar). The 7090 is compact
with comfortable handles with grips moulded into the design make it easy to control the
instrument whilst pumping up to pressure. Also available are a range of pumps suitable
for workshop use, that feature an ergonomic mode of operation. These models include
the the 7193 (vacuum to 40 bar pneumatic) and 7192 (vacuum to 25 bar pneumatic).
For process control signal simulation a practical tool like the Time Electronics handheld
7006 Loop-Mate is available as an option. It is a low cost, simple operation unit that provides
4 - 20 mA and 0 - 10 V signals at levels of 0 %, 10 %, 25 %, 50 %, 75 %, 90 %, 100 %.
It can also step through these set points automatically to allow hands-free calibration. It is
battery powered and compact, pocket sized and easy to carry in the field.
Features
• Vacuum to 10 bar versions available
• Accuracy 0.04 % of full scale
• Pneumatic
• 4 selectable pressure units plus mA
• Loop current measure
• 24/36 V loop power
• Over-pressure alarm
• RS-232 serial interface
• EasyCal software compatible
• Mains or battery powered
EasyCal Calibration Software
The 7016 can be controlled with readback via Time Electronics
EasyCal software to automate the calibration process. This
provides increased speed of calibration and consistency of
results. Produce traceable calibration certificates and test
reports for quality standards with additional uncertainty
information for ISO 17025 conformance.


Similar Part No. - 7090

ManufacturerPart #DatasheetDescription
logo
Bourns Electronic Solut...
7090 BOURNS-7090 Datasheet
460Kb / 2P
Network Interface Device
logo
Ohmite Mfg. Co.
7090 OHMITE-7090 Datasheet
143Kb / 1P
Rheostat and Tap Switch Hardware
logo
Time Electronics Ltd.
7090 TIME-ELECTRONICS-7090 Datasheet
538Kb / 1P
Maintenance Kits for 7090 and 7095 Pressure Pumps
07/22
7090 TIME-ELECTRONICS-7090 Datasheet
655Kb / 1P
7090 Pneumatic Calibration Pump
10/24
7090 TIME-ELECTRONICS-7090 Datasheet
986Kb / 2P
7010 Single Channel Pressure Calibrator
06/22
More results

Similar Description - 7090

ManufacturerPart #DatasheetDescription
logo
Intersil Corporation
ISL45042 INTERSIL-ISL45042_06 Datasheet
130Kb / 8P
LCD Module Calibrator
November 14, 2006
ISL45042 INTERSIL-ISL45042_07 Datasheet
141Kb / 8P
LCD Module Calibrator
August 29, 2007
logo
Extech Instruments Corp...
412355A EXTECH-412355A Datasheet
170Kb / 8P
Voltage Calibrator
412400 EXTECH-412400 Datasheet
133Kb / 8P
Multifunction Process Calibrator
CMM-17 EXTECH-CMM-17 Datasheet
253Kb / 1P
Process Calibrator MultiMeter
IRC350 EXTECH-IRC350 Datasheet
88Kb / 8P
Infrared Calibrator
logo
Agilent(Hewlett-Packard...
5530 HP-5530 Datasheet
1Mb / 14P
Dynamic Calibrator
logo
Intersil Corporation
ISL45042A INTERSIL-ISL45042A Datasheet
148Kb / 8P
LCD Module Calibrator
July 9, 2008
logo
Renesas Technology Corp
ISL45042A RENESAS-ISL45042A Datasheet
442Kb / 8P
LCD Module Calibrator
logo
Ralston Instruments.
QTFT-2MS0-MP RALSTON-QTFT-2MS0-MP Datasheet
463Kb / 1P
Adapt any pressure calibrator, pressure gauge or comparator to Quick-test easily
More results


Html Pages

1 2


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com