| Electronic Components Datasheet Search |
|
RPL1 Datasheet(PDF) 1 Page - LUMEL S.A. |
|
|
|||||||||||||||||||||||||||||
RPL1 Datasheet(HTML) 1 Page - LUMEL S.A. |
|
1 / 2 page ![]() Export department: Tel: +48 68 45 75 139/ 276/ 305/ 386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Słubicka 1 65-127 Zielona Góra POLAND WWW.LUMEL.COM.PL GALVANIC ISOLATION : Phase control O ON/OFF control OUTPUT: 125 A 2x Sup. FEATURES: O������ Output type Quantity Range Remarks Voltage (Master/Slave) 1 6 ...12 V non stabilized Relay 2 NO 60 mA/350 V, Ron = 35 , Uizol =1500 VRMS RPL1 POWER CONTROLLER Impulse control INPUT: 0..10 V 0..20 mA I����� Input type Quantity Range Remarks Synchronization input 230 V a.c. – version RPL1-xx1xx, 400 V a.c. – version RPL1-xx2xx, 500 V a.c. – version RPL1-xx3xx - Control voltage input 1 0...5 V 0...10 V Rin = 20 k Rin = 40 k Control current input 1 0(4)...20 mA Rin = 125 Control pulse input 1 0/4...32 V Rin = 20 k STOP signal input 1 4...8 V Rin = 1 k • For power control of resistive and resistive-inductive load(transformerconnectedtoresistiveloadortorectifier circuit). • Control mode: on/off (similar to solid state relay), pulse, phase. • Amplification of input control signal (SPAN). • Limitation of load current. • Overload protection. • Signalization of exceeding the maximum temperature of radiator. • Control of 3-phase load (requires two RPL1 controller units). E������ �� ����������� Soft Start ILIM RE72 RPL1 E��������� ���������� �� ����� ������� No. Max. output current Load supply voltage Max. load Lose power in thyristor 1 25 A 230 V / 50 Hz 400 V / 50 Hz 500 V / 50 Hz 5.7 kW 10.0 kW 12.5 kW < 40 W 2 40 A 230 V / 50 Hz 400 V / 50 Hz 500 V / 50 Hz 9.2 kW 16.0 kW 20.0 kW < 65 W 3 70 A 230 V / 50 Hz 400 V / 50 Hz 500 V / 50 Hz 16.0 kW 28.0 kW 35.0 kW < 120 W 4 125 A 230 V / 50 Hz 400 V / 50 Hz 500 V / 50 Hz 28.0 kW 50.0 kW 62.0 kW < 215 W • Leakage current in the thyristor circuit: < 20 mA • Load type: resistive or resistive-inductive (0.2<cos<1), compatible with the category of operational use AC-51 acc. to EN 60947-4-3 |
Similar Part No. - RPL1 |
|
Similar Description - RPL1 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |