Back Button ADM1070EB Datasheet HTML 2Page - Analog Devices ADM1070EB Datasheet HTML 3Page - Analog Devices ADM1070EB Datasheet HTML 4Page - Analog Devices ADM1070EB Datasheet HTML 5Page - Analog Devices ADM1070EB Datasheet HTML 6Page - Analog Devices ADM1070EB Datasheet HTML 7Page - Analog Devices ADM1070EB Datasheet HTML 8Page - Analog Devices ADM1070EB Datasheet HTML 9Page - Analog Devices ADM1070EB Datasheet HTML 10Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 12 page
background image
REV. 0
–6–
EVAL-ADM1070EB
EXAMPLE
The user wants to simulate a live insertion event with the
ADM1070 Evaluation Board. The user’s application operates
with a –48 V supply voltage. The plug-in board load can be
represented by a capacitive load of 100
µF. The ADM1070 will
be mounted on the backplane.
Set Up:
1. Resistor values of R1 = 39 k
Ω and R2 = 1 kΩ should be used
for a –48 V supply (see Table IV, page 11, ADM1070 data
sheet). Default resistor ratio used.
2. User’s maximum load current = 1.4 A. An RSENSE of
47 m
Ω gives maximum load current = 1.3 A (see Table I,
ADM1070 data sheet). Default value used.
3. Default timing values can be used. Switch 2 placed in
Position A.
The Evaluation Board should be set up as described in the Residing
On a Backplane section. A 100
µF load should set up (Default
Capacitor C4 = 100
µF load). To generate the wave forms below
on an oscilloscope, the following test points should be monitored.
GATE Waveform: Connect an oscilloscope probe between T7
(GATE) and T5 (–48 V).
SENSE Waveform: Connect an oscilloscope probe between
T8 (SENSE) and T10 (–48 V).
VOUT Waveform: Connect an oscilloscope between T11 (0 V)
and T12 (–48 V OUT).
The oscilloscope should be set to trigger on the rising edge of the
GATE voltage. A live insertion event can be modeled by inserting
the load board into the Evaluation Board Connector J9. Great
care should be taken when handling and connecting live boards.
CH2
100mV
5.00V
CH1
10.0V
CH3
M 500 s
CH1
2.8V
T
T
GATE
SENSE
VOUT
Figure 10. Live Insertion Waveforms



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com