| Electronic Components Datasheet Search |
|
DPST-NO Datasheet(PDF) 3 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
DPST-NO Datasheet(HTML) 3 Page - Omron Electronics LLC |
|
3 / 11 page ![]() 3 G9SB Connections Internal Connections G9SB-2002-A/C (24 VAC/VDC) G9SB-3012-A/C (24 VAC/VDC) G9SB-200-B/D (24 VAC/VDC) G9SB-301-B/D (24 VAC/VDC) G9SB-3010 (24 VDC) Note: 1. For 1-channel input with G9SB- @@@-B/D models, short terminals T12 and T22. It is not possible to wire G9SB- @@@2-A/C models for 1-channel input. 2. Always provide a protective ground externally, e.g., on the power supply. * Only G9SB-301@-@ models have terminals 33-34 and 41-42. Wiring of Inputs and Outputs Note: Grounding Be sure to ground externally, such as at the power supply. *1. Safety Inputs (1) G9SB-3010 directly cuts off power, and has no Safety Input. (2) For 1-channel input with G9SB- @@@-B/D, short circuit T12-T22 and then input. (3) With G9SB- @@@2-A/C, 1-channel input wiring is not possible. *2. Output Contacts G9SB-2002-A/C: Safety Output Contacts 13-14, 23-24. G9SB-3012-A/C: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. G9SB-200-B/D: Safety Output Contacts 13-14, 23-24. G9SB-301-B/D: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. G9SB-3010: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. K1 K2 K1 K1 K2 K2 K1 a a + - K2 TH SA A1 A2 T11 T12 T31 T32 13 23 (33) (41) 14 24 (34) (42) T21 T22 ** ** Control circuit K1 K2 K1 K1 K2 K2 K1 a a + - K2 TH SA A1 A2 T11 T12 T31 T32 13 (41) (33) 14 24 (34) (42) T21 T22 23 ** ** Control circuit K1 K2 K1 K1 K2 K2 K1 a a + - K2 TH SA A1 A2 T31 T32 13 23 33 41 14 24 34 42 Control circuit Signal name Terminal name Description of operation Power supply input A1, A2 The input terminals for power supply. Connect the power source to the A1 and A2 terminals. DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side. Safety input 1 *1T11, T12 To set the safety outputs in the ON state, the ON state signals must be input to both safety input 1 and safety input 2. Otherwise the safety outputs cannot be in the ON state. Safety input 2 *1T21, T22 Feedback/reset input T31, T32 To set the safety outputs in the ON state, the ON state signal must be input to T31 - T32. Otherwise the safety outputs cannot be in the ON state. Instantaneous safety outputs See below. *2 Turns ON/OFF according to the state of the safety inputs and feedback/reset inputs. Auxiliary output See below. *2 Synchronized with Instant Safety Output. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |