| Electronic Components Datasheet Search |
|
LT5512 Datasheet(PDF) 2 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT5512 Datasheet(HTML) 2 Page - Analog Devices |
|
2 / 3 page ![]() QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 933A HF/VHF/UHF DOWNCONVERTING MIXER 2 APPLICATION NOTE ABSOLUTE MAXIMUM INPUT RATING Supply Voltage ..................................................... 5.5V Enable Voltage.................................–0.3V to V CC+0.3V LO+ to LO- Differential Voltage .......................... ±1.5V ..................................................(+6dBm equivalent) RF+ to RF- Differential Voltage........................... ±0.7V ................................................(+11dBm equivalent) FREQUENCY RANGE Demonstration circuit 933A is optimized for 140MHz RF to 10MHz IF downconversion with high-side LO injection. However, it can also be used at other fre- quencies. The RF input port is well matched with better than 10dB return loss over the frequency range from 100MHz to 195MHz. The simple resistive LO input matching is robust up to 1.5GHz. The IF output port has better than 10dB return loss from 500kHz to 95MHz. With proper matching, the RF, LO and IF ports can be tuned for operation at other frequencies. Please refer to the LT5512 datasheet Applications Information section. TEST EQUIPMENT AND SETUP Refer to Figure 1 for proper measurement equipment setup. Use high performance signal generators with low harmonic output for 2-tone measurements. Other- wise, low-pass filters at the signal generator outputs should be used to suppress higher-order harmonics. High quality combiners that provide broadband 50 Ω termination on all ports and have good port-to-port isolation should be used. Attenuators on the outputs of the signal generators are recommended to further improve source isolation, to prevent the sources from modulating each other and generating intermodula- tion products. Spectrum analyzers can produce significant internal dis- tortion products if they are overdriven. Generally, spec- trum analyzers are designed to operate at their best with about –30dBm to -40dBm at their input. Sufficient spectrum analyzer input attenuation should be used to avoid saturating the instrument. Before performing measurements on the DUT, the system performance should be evaluated to ensure that: 1) a clean input signal is obtained and 2) the spectrum analyzer internal distortion is minimized. QUICK START PROCEDURE Demonstration circuit 933A is easy to set up to evalu- ate the performance of the LT5512. Refer to Figure 1 for proper measurement equipment setup and follow the procedure below: 1. Connect signal generator outputs to demo board RFin port (SMA connector J1) and LOin port (SMA connector J2) via coaxial cable. 2. Connect demo board IFout port (SMA connector J3) to spectrum analyzer input via coaxial cable. 3. Connect DC power supply negative (-) output to demo board GND pin. 4. Connect DC power supply positive (+) output (4.5V to 5.25V) to demo board Vcc pin. NOTE: Do not exceed 5.5V, the absolute maximum supply voltage. 5. Using a jumper cable, connect demo board Vcc pin to EN pin. Now the detector is enabled (on) and is ready for measurement. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |