Back Button LTC2959 Datasheet HTML 11Page - Analog Devices LTC2959 Datasheet HTML 12Page - Analog Devices LTC2959 Datasheet HTML 13Page - Analog Devices LTC2959 Datasheet HTML 14Page - Analog Devices LTC2959 Datasheet HTML 15Page - Analog Devices LTC2959 Datasheet HTML 16Page - Analog Devices LTC2959 Datasheet HTML 17Page - Analog Devices LTC2959 Datasheet HTML 18Page - Analog Devices LTC2959 Datasheet HTML 19Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 15 / 19 page
background image
LTC2959
15
Rev. A
For more information LTC2959
APPLICATIONS INFORMATION
Start and Stop Conditions
When the bus is idle, both SCL and SDA must be high.
A bus master signals the beginning of a transmission
with a START condition by transitioning SDA from high
to low while SCL is high. When the master has finished
communicating with the slave, it issues a STOP condition
by transitioning SDA from low to high while SCL is high.
The bus is then free for another transmission. When the
bus is in use, it stays busy if a repeated START (Sr) is gen-
erated instead of a STOP condition. The repeated START
(Sr) conditions are functionally identical to the START (S).
Write Protocol
The master begins a write operation with a START condi-
tion followed by the seven-bit slave address 1100011 and
the R/W bit set to zero. The LTC2959 acknowledges this
by pulling SDA low and the master sends a command byte
which indicates which internal register the master is to
write. The LTC2959 acknowledges and latches the com-
mand byte into its internal register address pointer. The
master delivers the data byte, the LTC2959 acknowledges
once more and latches the data into the desired register.
The transmission is ended when the master sends a STOP
condition. If the master continues by sending a second
data byte instead of a stop, the LTC2959 acknowledges
again, increments its address pointer and latches the sec-
ond data byte in the following register.
Multi-byte quantities can only be written using a suffi-
ciently long I2C burst write.
Read Protocol
The master begins a read operation with a START con-
dition followed by the seven-bit slave address 1100011
and the R/W bit set to zero. The LTC2959 acknowledges
and the master sends a command byte which indicates
which internal register the master is to read. The LTC2959
acknowledges and then latches the command byte into its
internal register address pointer. The master then sends a
repeated START condition followed by the same seven-bit
address with the R/W bit now set to one. The LTC2959
acknowledges and sends the contents of the requested
register. The transmission is ended when the master
sends a STOP condition. If the master acknowledges
the transmitted data byte, the LTC2959 increments its
address pointer and sends the contents of the following
register.
Multi-byte quantities should be read using a sufficiently
long I2C burst read.
I2C Timeout
The device includes a timer to ensure that it does not hold
SDA low indefinitely in the absence of a clock. This tim-
eout interval is typically 51.2ms. When no clock pulses
are received for the duration of this interval, the LTC2959
releases the SDA pin and the communication interface
is reset.
Alert Response Protocol
In a system where several slaves share a common inter-
rupt line, the master can use the alert response address
(ARA) to determine which device initiated the interrupt.
The master initiates the ARA procedure with a START con-
dition and the special 7-bit ARA bus address (0001100)
followed by the read bit (R) = 1. If the LTC2959 is assert-
ing an alert, it acknowledges and responds by sending its
7-bit bus address (1100011) and a 1. While it is sending
its address, it monitors the SDA pin to see if another
device is sending an address at the same time using
standard I2C bus arbitration. If the LTC2959 is sending
a 1 and reads a 0 on the SDA pin on the rising edge of
SCL, it assumes another device with a lower address is
sending and the LTC2959 immediately aborts its transfer
and waits for the next ARA cycle to try again. If transfer
is successfully completed, the LTC2959 will stop pulling
down the GPIO pin and will not respond to further ARA
requests until a new Alert event occurs.
Reconfiguring the LTC2959’s GPIO pin as an analog or
a digital input immediately clears the Alert pull-down.
Afterwards, when the GPIO pin is configured as a digital
output again, the LTC2959 will only pull down GPIO when
a new alert event occurs.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com