16 / 20 page ![]() DP-100 15 PRECAUTIONS FOR PROPER USE PRO mode Setting item Description Reset setting ECO mode setting Linked display color switching (standard type only) Display refresh rate switching Hysteresis fix value switching Setting check code Setting copy mode Table of codes — — — —— —— — — — — — — ADJ. NO OFF OFF P-1, Lo-1 NC NO Hi-1 NO NC P-2, Lo-2 NC NO Hi-2 NO NC NC NC NO EASY EASY Analog voltage output / External input NO / NC switching Comparative output 2 output mode Comparative output 1 output mode NO / NC switching Display color for main display Threshold value display Display color linking 2.5 ms MPa 250 ms OFF 5 ms kPa 500 ms STD 10 ms kgf/cm2 1,000 ms FULL 25 ms bar 50 ms psi 100 ms mmHg 250 ms inchHg 500 ms 1,000 ms 5,000 ms If the mode selection key is pressed and held for 5 seconds in RUN mode, the mode will switch to PRO mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Sub display switching Changes the information in the sub display during RUN mode operation to the desired alphanumeric display. Changes the display refresh rate for the pressure value displayed in the main display. Sets the hysteresis for EASY mode and window comparator mode. (8 steps) Allows the display color for the main display to be switched in line with the output operation for comparative output 1 or comparative output 2. Allows power consumption to be reduced by dimming the display or turning it off. Allows the setting details to be checked via codes. Allows the setting details for the master sensor to be copied to slave sensors. Resets the settings to the factory settings. 1st digit 2nd digit 3rd digit 4th digit Standard type only Multi-function type Standard type Hysteresis Hysteresis Red when ON Comparative output 1 Comparative output 2 Comparative output 1 Comparative output 2 Comparative output 1 Comparative output 2 Comparative output 1 Comparative output 2 Green when ON Always red Always green Analog voltage output Auto- reference Remote zero-adjustment Analog current output Window comparator Window comparator 5th digit 6th digit 7th digit 8th digit Response time Unit switching Display refresh rate ECO mode If the mode selection key is pressed and held for 2 seconds in RUN mode, the mode will switch to MENU SETTING mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Others RUN mode MENU SETTING mode This product has been developed / produced for industrial use. Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. Comparative output 1 output mode setting Setting item Description Sets the output mode for comparative output 1. Unit switching Pressure unit can be changed. NO / NC switching Response time setting Comparative output 2 output mode setting (standard type only) Sets the output mode for comparative output 2. Display color switching for main display Analog output / external input switching (multi-function type only) Allows the color for the main display to be changed. The colors can be set to ‘red / green’ or ‘green / red’ to correspond to ON / OFF output, or it can be fixed at ‘red’ or ‘green’ all the time. Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Sets normally open (NO) or normally closed (NC). Allows switching between analog voltage output / analog current output, and auto-reference input / remote zero-adjust-ment input. Setting item Description Threshold value setting Zero-adjustment function Key lock function Peak hold / bottom hold function Stops key operations from being accepted. The threshold values for ON / OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. — — — — — — — — — — — — — — — — — |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |