Electronic Components Datasheet Search
  English  ▼

X  

MCE03US48 Datasheet(PDF) 2 Page - XP Power Limited

Part # MCE03US48
Description  MCE03 Series
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  XPPOWER [XP Power Limited]
Direct Link  http://www.xppower.com
Logo XPPOWER - XP Power Limited

MCE03US48 Datasheet(HTML) 2 Page - XP Power Limited

  MCE03US48 Datasheet HTML 1Page - XP Power Limited MCE03US48 Datasheet HTML 2Page - XP Power Limited MCE03US48 Datasheet HTML 3Page - XP Power Limited MCE03US48 Datasheet HTML 4Page - XP Power Limited MCE03US48 Datasheet HTML 5Page - XP Power Limited  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
AC-DC POWER SUPPLIES
2
MCE03 Series
Output
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Output Voltage
3.3
48
VDC
Initial Set Accuracy
3/2
%
3% for 3V3 & 5V models, 2% for others at 50% load
Minimum Load
0
A
No minimum load required
Line Regulation
1
%
Load Regulation
6/4
6% for 3V3 & 5V models, 4% for other models
Start Up Delay
2
s
Start Up Rise Time
35
ms
Hold Up Time
8
14
ms
At full load and 115VAC
Transient Response
4
%
Deviation, recovery within 1% in less than 500μs for a 25% load
change
Ripple & Noise
100
mV pk-pk
3.3-9V models, 20MHz bandwidth
1
% pk-pk
12V to 15V models, 20MHz bandwidth
1.5
% pk-pk
24V to 48V models, 20MHz bandwidth
Patient Leakage Current
65
μA
At 264VAC, 60Hz
Overvoltage Protection
115
145
% Vnom
220% typical for 3V3 model, auto recovery
Overload Protection
110
190
%
Short Circuit Protection
Trip & Restart (hiccup mode)
Temperature Coefficient
0.05
%/°C
Summary
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage Range
80
264
VAC
Derate from 100% at 90 VAC to 90% at 80VAC
No Load Input Power
0.3
W
Efficiency
80
%
Model dependent, see Models & Ratings
Operating Temperature
-25
+70
°C
Derate output linearly from 100% at 50°C to 50% at 70°C
EMC
EN55011 Level B Conducted & Radiated, EN61000-3-2, EN61000-3-3, EN60601-1-2
Safety Approvals
IEC60601-1, EN60601-1, ES60601-1
Input
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage Range
80
264
VAC
Derate from 100% at 90VAC to 90% at 80VAC
Input Frequency
47
63
Hz
Input Current - Full Load
0.06/0.04
A rms
At 115/230VAC
No Load Input Power
0.3
W
Inrush Current
40
A
At 230VAC, cold start 25°C
Earth Leakage Current
Class II construction no earth
Input Protection
External T1.0 A/300 VAC fuse required in line and neutral



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com