| Electronic Components Datasheet Search |
|
MP2722 Datasheet(PDF) 24 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP2722 Datasheet(HTML) 24 Page - Monolithic Power Systems |
|
24 / 49 page ![]() MP2722 – 5A, SINGLE-CELL, I2C-CONTROLLED BUCK CHARGER W/ USB TYPE-C DRP MP2722 Rev. 1.0 MonolithicPower.com 24 11/3/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. The debounced CC pin status can be read the in CC_SNK_STAT and CC_SRC_STAT bits. Any change in these bits is followed by a maskable INT pulse. Forced Input Current Limit When an input source is plugged in during sink mode, the MP2722 runs the start-up sequence and input source type detection. After detection finishes, IIN_LIM is automatically generated. The IIN_LIM result is returned by the IIN_LIM bits. If the host does not want to use the automatically generated IIN_LIM, there are two ways to set IIN_LIM to different values via configuring either the IIN_MODE or IIN_LIM bits. If the IIN_MODE bits are set to 000, the MP2722 runs with the automatically generated IIN_LIM (returned by the IIN_LIM bits). However, once the VIN_RDY bit is set, the host can override the IIN_LIM bits to set IIN_LIM to any value. This requires host involvement every time the converter starts up. If the IIN_MODE bits are set to other values, IIN_LIM is forced and fixed. For example, if the IIN_MODE bits are set to 101, the device always runs with a fixed 2000mA IIN_LIM, ignoring the input source type detection. Legacy Cable Detection In sink mode, the MP2722 supports a legacy cable detection function. If the input source is plugged in through a Type-C to Type-C (C-C) cable, then VIN is present after the CC1 and CC2 pins make contact for ≥100ms. The adapter ’s Type-C port requires a debounce time (tCC_DEBOUNCE) (between 100ms and 200ms) before it can turn on the VBUS output. If a legacy Type-A to Type-C (A-C) cable is used, there is no debounce time. A legacy cable timer (tLEGACY, 75ms) starts once the CC1 or CC2 pin detects a vRd connect voltage (>0.2V). If an input source provides VBUS before tCC_DEBOUNCE expires, or VIN is present before the CC1 and CC2 pins make contact, then the LEGACYCABLE bit is set to 1 once a valid input source is detected (i.e. VIN is between VIN_UV and VIN_OV after 15ms). This action is followed by a maskable an INT pulse. The LEGACYCABLE bit is reset to 0 if VIN drops below VIN_UV or exceeds VIN_OV. With legacy cable detection, the host can know the cable type. An advantage of this function is that if the legacy cable is non-compliant with the specification (e.g. if the CC pin is shorted to VBUS or Rp is incorrect), the host can adjust the device’s IIN_LIM with the DPDM detection results. Input Impedance Test The MP2722 supports an input impedance testing function. By sourcing a current on the IN pin, the device can detect the impedance on the connecter receptacle (water detection). The host can write 1 to the VIN_SRC_EN bit to turn on the input impedance test by sourcing a current to the IN pin. The testing current can be configured via the IVIN_SRC bits. If VIN rises to the threshold configured via the VIN_TEST bit, then VIN_TEST_HIGH is set to 1 and latched. This is followed by an INT pulse. The host can write 0 to the VIN_SRC_EN bit to turn off the test current source and clear the VIN_TEST_HIGH bit. The VIN_SRC_EN bit can only be effective when neither the buck nor boost is operating, and the current source’s maximum pull-up voltage is 2.5V. If VIN > VIN_UV is detected during the test, then the VIN_SRC_EN and VIN_TEST_HIGH bits are reset to 0 and the test ends immediately. If boost mode is enabled during the test, then the VIN_SRC_EN and VIN_TEST_HIGH bits are reset to 0 and the test ends immediately. The advantage of the input impedance function is that the device can provide the information on the connector ’s impedance or moisture status. A Type-C connector can corrode when exposed to moisture, especially in source or DRP mode with a current on the CC pins. Software detects moisture conditions to allow the device to disable charging, the boost, or the Type-C block. Lock Function The MP2722 supports a lock function that limits the value of some key parameters (prevents accidental I2C writing). The battery regulation voltage, constant-current charge current, pre- charge current, and JEITA voltage/current settings are some of these parameters. To enable the lock function, the host can set the above parameters to a target value, then write |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |