20 / 26 page ![]() DC and AC parameters M41T00S 20/26 Table 9. Power down/up AC characteristics Table 10. Power down/up trip points DC characteristics Figure 14. Bus timing requirements sequence Symbol Parameter(1)(2) 1. VCC fall time should not exceed 5 mV/µs. 2. Valid for ambient operating temperature: TA = –40 to 85°C; VCC = 2.7 to 5.5 V (except where noted). Min Typ Max Unit tPD SCL and SDA at VIH before power down 0 nS trec SCL and SDA at VIH after power up 10 µS Sym Parameter(1)(2) 1. All voltages referenced to VSS. 2. Valid for ambient operating temperature: TA = –40 to 85°C; VCC = 2.7 to 5.5 V (except where noted). Min Typ Max Unit VPFD Power-fail deselect 2.5 2.6 2.7 V Hysteresis 25 mV VSO Battery backup switchover voltage (VCC < VBAT; VCC < VPFD) VBAT < VPFD VBAT V VBAT > VPFD VPFD V Hysteresis 40 mV AI00589 SDA P tSU:STO tSU:STA tHD:STA SR SCL tSU:DAT tF tHD:DAT tR tHIGH tLOW tHD:STA tBUF S P |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|