149 / 366 page ![]() 2-73 REJ09B0018-0200Z Rev.2.00 Jun 21, 2004 7540 Group APPLICATION 2.5 Timer Y and timer Z 2.5.3 Timer mode (timer Y and timer Z) The basic operation of Timer Y and Timer Z are the same. In this section, Timer Y is explained. (1) Operation description Prescaler Y counts the count source selected by the timer Y count source selection bits. Each time the count clock is input, the contents of Prescaler Y is decremented by 1. When the contents of Prescaler Y reach “0016”, an underflow occurs at the next count clock, and the prescaler Y latch is reloaded into Prescaler Y and count continues. The division ratio of Prescaler Y is 1/(n+1) provided that the value of Prescaler Y is n. The contents of Timer Y is decremented by 1 each time the underflow signal of Prescaler Y is input. When the contents of Timer Y reach “0016”, an underflow occurs at the next count clock, and the timer Y primary latch is reloaded into Timer Y and count continues. (In the timer mode, the contents of timer Y primary latch is counted. Timer Y secondary latch is not used in this mode.) The division ratio of Timer Y is 1/(m+1) provided that the value of Timer Y is m. Accordingly, the division ratio of Prescaler Y and Timer Y is provided as follows that the value of Prescaler Y is n and the value of Timer Y is m. In the timer mode, writing to “latch only” or “latches and Prescaler Y and timer Y primary” can be selected by the setting value of the timer Y write control bit. Timer Y can stop counting by setting “1” to the timer Y count stop bit. Also, when timer Y underflows, the timer Y interrupt request bit is set to “1”. Timer Y reloads the value of latch when counting is stopped by the timer count stop bit. (When timer is read out while timer is stopped, the value of latch is read. The value of timer can be read out only while timer is operating.) (2) Timer mode setting method Figure 2.5.19 shows the setting method for timer mode of Timer Y. When Timer Z is used, registers are set by the same method. Division ratio = 1 (n+1) ✕ (m+1) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |