CY29973
Document #: 38-07291 Rev. *C
Page 6 of 9
Power Management
The individual output enable or freeze control of the CY29973 allows the user to implement unique power management schemes into
the design. The outputs are stopped in the logic ‘0’ state when the freeze control bits are activated. The serial input register contains
one programmable freeze enable bit for 12 of the 14 output clocks. The QC0 and FB_OUT outputs can not be frozen with the serial
port, this avoids any potential lock up situation must an error occur in the loading of the serial data. An output is frozen when a logic
‘0’ is programmed and enabled when a logic ‘1’ is written. The enabling and freezing of individual outputs is done in such a manner
as to eliminate the possibility of partial “runt” clocks.
The serial input register is programmed through the SDATA input by writing a logic ‘0’ start bit followed by 12 NRZ freeze enable bits.
The period of each SDATA bit equals the period of the free running SCLK signal. The SDATA is sampled on the rising edge of SCLK.
Figure 2. Control Bit Map
Absolute Maximum Conditions[3]
Maximum Input Voltage Relative to VSS:.............. VSS - 0.3V
Maximum Input Voltage Relative to VDD:............. VDD + 0.3V
Storage Temperature: ................................ - 65
°C to + 150°C
Operating Temperature:................................ - 40
°C to +85°C
Maximum ESD protection............................................... 2 kV
Maximum Power Supply:................................................ 5.5V
Maximum Input Current:
................................................ ± 20 mA
This device contains circuitry to protect the inputs against
damage due to high static voltages or electric field; however,
precautions must be taken to avoid application of any voltage
higher than the maximum rated voltages to this circuit. For proper
operation, Vin and Vout must be constrained to the range:
VSS < (Vin or Vout) < VDD
Unused inputs must always be tied to an appropriate logic
voltage level (either VSS or VDD).
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D0-D3 are the control bits for QA0-QA3, respectively
D4-D7 are the control bits for QB0-QB3, respectively
D8-D10 are the control bits for QC1-QC3, respectively
D11 is the control bit for SYNC
Start
Bit
DC Electrical Specifications V
DD = 2.9V to 3.6V, VDDC = 3.3V ±10%, TA = - 40°C to +85°C
Parameter
Description
Conditions
Min
Typ.
Max
Unit
VIL
Input Low Voltage
VSS
–0.8
V
VIH
Input High Voltage
2.0
–
VDD
V
VPP
Peak-to-Peak Input Voltage
PECL_CLK
300
–
1000
mV
VCMR
Common Mode Range PECL_CLK[4]
VDD – 2.0
–
VDD – 0.6
V
IIL
Input Low Current[5]
–
–
–120
μA
IIH
Input High Current[5]
––
120
μA
VOL
Output Low Voltage[6]
IOL = 20 mA
–
–
0.5
V
VOH
Output High Voltage[6]
IOH = –20 mA
2.4
–
–
V
IDDQ
Quiescent Supply Current
–10
15
mA
IDDA
PLL Supply Current
VDD only
–
15
20
mA
Notes
3. Multiple Supplies: The voltage on any input or IO pin cannot exceed the power pin during power up. Power supply sequencing is NOT required.
4. The VCMR is the difference from the most positive side of the differential input signal. Normal operation is obtained when the “High” input is within the VCMR range
and the input lies within the VPP specification.
5. Inputs have pull up/pull down resistors that effect input current.
6. Driving series or parallel terminated 50
Ω (or 50Ω to V
DD/2) transmission lines.
[+] Feedback