| Electronic Components Datasheet Search |
|
SC820 Datasheet(PDF) 17 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC820 Datasheet(HTML) 17 Page - Semtech Corporation |
|
17 / 21 page ![]() SC820 17 Applications Information (continued) the pre-charge current while the battery voltage is below the pre-charge threshold. This is because the low input voltage will also compress the pre-charge threshold inter- nal reference voltage to below the battery voltage. This will prematurely advance the charger logic from pre- charge current regulation to fast-charge regulation, and the charge current will exceed the safe level recom- mended for pre-charge conditioning. The low deselection falling threshold (VT ADsel-F ) permits the adapter voltage to be pulled down to just above the battery voltage by the charging load whenever the adapter current limit is less than the programmed fast- charge current. The SC820 should be operated with adapter voltage below the rising selection threshold (VT ADSel-R ) only if the low input voltage is the result of adapter current limiting. This implies that the VAD voltage first exceeds VT ADsel-R to begin charging, and is subsequently pulled down to just above the battery voltage by the charging load. Interaction of Thermal Limiting and Current Limited Adapter Charging To permit the charge current to be limited by the adapter, it is necessary that the adapter input fast-charge current be programmed greater than the maximum adapter current, (I AD-LIM ). In this configuration, the CC regulator will operate with its pass device fully on (in saturation, also called “dropout”). The voltage drop from VAD to BAT is determined by the product of the minimum R DS-ON of the pass device multiplied by the adapter supply current. In dropout, the power dissipation in the SC820 is P ILIM = (minimum R DS-ON ) x (I AD-LIM )2. Since minimum R DS-ON does not vary with battery voltage, dropout power dissi- pation is constant throughout the CC portion of the charge cycle while the adapter remains in current limit. The SC820 junction temperature will rise above ambient by P ILIM x θ JA . If the device temperature rises to the tem- perature at which the thermal limiting control loop limits charging current (rather than the current being limited by the adapter), the input voltage will rise to the adapter regulation voltage. The power dissipation will increase so that the thermal limit regulation will further limit charge current. This will keep the adapter in voltage regulation for the remainder of the charge cycle. To ensure that the adapter remains in current limit, the internal device temperature must never rise to T TL . This implies that θ JA must be kept small enough to ensure that T J = T A + (P ILIM × θ JA ) < T TL . VUSB Under-Voltage Load Regulation VUSB pin UVLR prevents the battery charging current from overloading the USB Vbus network, regardless of the pro- grammed fast-charge value. When the VUSB input is selected, the SC820 monitors the input voltage (V VUSB ) and reduces the charge current as necessary to keep V VUSB at or above the UVLR limit (V VUSB_UV_LIM ). UVLR operates like a fourth output constraint (along with CC, CV, and CT con- straints), but it is active only when the VUSB input is selected. If the VUSB voltage is externally pulled below V USB_UV_LIM while the VAD input is absent, the UVLR feature will reduce the charging current to zero. This condition will not be interpreted as termination and will not result in an end-of- charge indication. The STATB pin will remain asserted as if charging is continuing. This prevents repetitive indica- tions of end-of-charge alternating with start-of-charge in the case that the external VUSB load is removed or is intermittent. Short Circuit Protection The SC820 can tolerate a BAT pin short circuit to ground indefinitely. The current into a ground short is approxi- mately 10mA. During charging, a short to ground applied to the active current programming pin (IPRGM or IPUSB) is detected, while a short to ground on the inactive programming pin is ignored. Pin-short detection on an active current pro- gramming pin forces the SC820 into reset, turning off the output. A pin-short on either programming pin will prevent startup regardless of the charging input selected. When the IPRGM or IPUSB pin-short condition is removed, the charger begins normal operation automatically without input power cycling. Over-Current Protection Over-current protection is provided in all modes of opera- tion, including CV regulation. The output current is limited to either the pre-charge or the fast-charge current (as |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |