18 / 32 page ![]() LTC3555/LTC3555-X 18 3555fd 1022 times the current in the PROG pin. The program resistor and the charge current are calculated using the following equations: R PROG = 1022V I CHG , I CHG = 1022V R PROG In either the constant-current or constant-voltage charging modes, the voltage at the PROG pin will be proportional to the actual charge current delivered to the battery. There- fore, the actual charge current can be determined at any time by monitoring the PROG pin voltage and using the following equation: I BAT = V PROG R PROG • 1022 In many cases, the actual battery charge current, IBAT, will be lower than ICHG due to limited input power available and prioritization with the system load drawn from VOUT. Charge Status Indication The CHRG pin indicates the status of the battery charger. Four possible states are represented by CHRG which in- clude charging, not charging, unresponsive battery, and battery temperature out of range. The signal at the CHRG pin can be easily recognized as one of the above four states by either a human or a mi- croprocessor. An open-drain output, the CHRG pin can drive an indicator LED through a current limiting resistor for human interfacing or simply a pull-up resistor for microprocessor interfacing. To make the CHRG pin easily recognized by both humans and microprocessors, the pin is either low for charging, high for not charging, or it is switched at high frequency (35kHz) to indicate the two possible faults, unresponsive battery and battery temperature out of range. When charging begins, CHRG is pulled low and remains low for the duration of a normal charge cycle. When charging is complete, i.e., the BAT pin reaches the float voltage and the charge current has dropped to one tenth of the programmed value, the CHRG pin is released (Hi-Z). If a fault occurs, the pin is switched at 35kHz. While switching, its duty cycle is modulated between a low and high value at a very low frequency. The low and high duty cycles are disparate enough to make an LED appear to be on or off thus giving the appearance of “blinking”. Each of the two faults has its own unique “blink” rate for human recognition as well as two unique duty cycles for machine recognition. The CHRG pin does not respond to the C/10 threshold if the LTC3555 family is in VBUS current limit. This prevents false end-of-charge indications due to insufficient power available to the battery charger. Table 1 illustrates the four possible states of the CHRG pin when the battery charger is active. Table 1. CHRG Signal STATUS FREQUENCY MODULATION (BLINK) FREQUENCY DUTY CYCLES Charging 0Hz 0Hz (Lo-Z) 100% Not Charging 0Hz 0Hz (Hi-Z) 0% NTC Fault 35kHz 1.5Hz at 50% 6.25% to 93.75% Bad Battery 35kHz 6.1Hz at 50% 12.5% to 87.5% An NTC fault is represented by a 35kHz pulse train whose duty cycle varies between 6.25% and 93.75% at a 1.5Hz rate. A human will easily recognize the 1.5Hz rate as a “slow” blinking which indicates the out-of-range battery temperature while a microprocessor will be able to decode either the 6.25% or 93.75% duty cycles as an NTC fault. If a battery is found to be unresponsive to charging (i.e., its voltage remains below 2.85V for 1/2 hour), the CHRG pin gives the battery fault indication. For this fault, a human would easily recognize the frantic 6.1Hz “fast” blink of the LED while a microprocessor would be able to decode either the 12.5% or 87.5% duty cycles as a bad battery fault. Note that the LTC3555 family is a three terminal PowerPath product where system load is always prioritized over battery charging. Due to excessive system load, there may not be sufficient power to charge the battery beyond the trickle charge threshold voltage within the bad battery timeout period. In this case, the battery charger will falsely indicate a bad battery. System software may then reduce the load and reset the battery charger to try again. Although very improbable, it is possible that a duty cycle reading could be taken at the bright-dim transition (low duty cycle to high duty cycle). When this happens the OPERATION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |