| Electronic Components Datasheet Search |
|
SSM Datasheet(PDF) 2 Page - Systemsensor advanced ideas. |
|
|
|||||||||||||||||||||||||||||
SSM Datasheet(HTML) 2 Page - Systemsensor advanced ideas. |
|
2 / 2 page ![]() 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0260-008 • 4/07 • #1676 Ordering Information UL/FM Model No. ULC/Canadian Model No. Description SSM24-6 SSM24-6A Bell, 6˝, 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8˝, 24VDC, Polarized, 80dBA SSM24-10 SSM24-10A Bell, 10˝, 24VDC, Polarized, 81dBA SSV120-6 SSV120-6A Bell, 6˝, 120VAC, 85dBA SSV120-8 SSV120-8A Bell, 8˝, 120VAC, 82dBA SSV120-10 SSV120-10A Bell, 10˝, 120VAC, 82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors SSM/SSV Specifications Architectural/Engineering Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 6˝/8˝/10˝ (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4˝ square electrical box having a maximum projection of 2½˝. Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Physical/Operating Specifications Operating Temperature Range –31°F to 140°F Operating Voltage SSM series: 24 VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty 3 years Electrical Specifications Model Gong Diameter (inches) Nominal Voltage Operating Voltage Limit Maximum Current Sound Output (dBA) SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-31.1mA/ FWR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33VDC DC-31.1mA/ FWR-53.5mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-31.1mA/ FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96 to 132VAC 53mA 82 * Sound output measured at Underwriter Laboratories, as specified in UL464 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |