  CD74FCT374M Datasheet HTML 1Page - Texas Instruments CD74FCT374M Datasheet HTML 2Page - Texas Instruments CD74FCT374M Datasheet HTML 3Page - Texas Instruments CD74FCT374M Datasheet HTML 4Page - Texas Instruments CD74FCT374M Datasheet HTML 5Page - Texas Instruments CD74FCT374M Datasheet HTML 6Page - Texas Instruments CD74FCT374M Datasheet HTML 7Page - Texas Instruments CD74FCT374M Datasheet HTML 8Page - Texas Instruments  
Zoom Inzoom in Zoom Outzoom out
 4 / 8 page
background image
8-4
Switching Specifications Over Operating Range FCT Series tr, tf = 2.5ns, CL = 50pF, RL (Figure 4) (Note 6)
PARAMETER
SYMBOL
VCC (V)
25oC0oC TO 70oC
UNITS
TYP
MIN
MAX
Propagation Delays
Clock to Q
tPLH, tPHL
5
6.6
2
10
ns
Output Disable to Q
tPLZ, tPHZ
5
6
1.5
8
ns
Output Enable to Q
tPZL, tPZH
5
9
1.5
12.5
ns
Power Dissipation Capacitance
CPD
(Note 7)
-33-
-
pF
Minimum (Valley) VOHV During Switching of
Other Outputs (Output Under Test Not Switching)
VOHV
5
0.5
-
-
V
Maximum (Peak) VOLP During Switching of
Other Outputs (Output Under Test Not Switching)
VOLP
51
-
-
V
Input Capacitance
CI
---
10
pF
Three State Output Capacitance
CO
---
15
pF
NOTES:
6. 5V: Min is at 5.25V for 0oC to 70oC, Max is at 4.75V for 0oC to 70oC, Typ is at 5V.
7. CPD, measured per flip-flop, is used to determine the dynamic power consumption.
PD (per package) = VCC ICC + Σ(VCC
2 f
I CPD + VO
2 f
O CL + VCC ∆ICC D) where:
VCC = supply voltage
∆ICC = flow through current x unit load
CL = output load capacitance
D = duty cycle of input high
fO = output frequency
fI = input frequency
Prerequisite for Switching
PARAMETER
SYMBOL
VCC (V)
25oC0oC TO 70oC
UNITS
TYP
MIN
MAX
Setup Time Data to Clock
tSU
5
(Note 8)
-2-
ns
Data to Clock Hold Time
tH
5-2-
ns
Clock Pulse Width
tW
5-7-
ns
Maximum Clock Frequency
fMAX
5
-
70
-
MHz
NOTE:
8. 5V: Minimum is at 4.75V for 0oC to 70oC, Typical is at 5V.
CD74FCT374



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com