Electronic Components Datasheet Search
  English  ▼

X  

MSP430C323IPG Datasheet(PDF) 12 Page - Texas Instruments

Part # MSP430C323IPG
Description  MIXED SIGNAL MICROCONTROLLER
PDF  33 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

MSP430C323IPG Datasheet(HTML) 12 Page - Texas Instruments

Back Button MSP430C323IPG Datasheet HTML 8Page - Texas Instruments MSP430C323IPG Datasheet HTML 9Page - Texas Instruments MSP430C323IPG Datasheet HTML 10Page - Texas Instruments MSP430C323IPG Datasheet HTML 11Page - Texas Instruments MSP430C323IPG Datasheet HTML 12Page - Texas Instruments MSP430C323IPG Datasheet HTML 13Page - Texas Instruments MSP430C323IPG Datasheet HTML 14Page - Texas Instruments MSP430C323IPG Datasheet HTML 15Page - Texas Instruments MSP430C323IPG Datasheet HTML 16Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 33 page
background image
MSP430C32x, MSP430P325A
MIXED SIGNAL MICROCONTROLLER
SLAS219B – MARCH 1999 – REVISED MARCH 2000
12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
8-bit Timer/Counter
The 8-bit interval timer supports three major functions for the application:
D Serial communication or data exchange
D Pulse counting or pulse accumulation
D Timer
The 8-bit Timer/Counter peripheral includes the following major blocks: an 8-bit Up-Counter with preload
register, an 8-bit control register, an Input clock selector, an edge detection (e.g. Start bit detection for
asynchronous protocols), and an input and output data latch, triggered by the carry-out-signal from the 8-bit
counter.
The 8-bit counter counts up with an input clock which is selected by two control bits from the control register.
The four possible clock sources are MCLK, ACLK, the external signal from terminal P0.1, and the signal from
the logical AND of MCLK and terminal P0.1.
Two counter inputs (load, enable) control the counter operation. The load input controls load operations. A
write-access to the counter results in loading the content of the preload register into the counter. The software
writes or reads the preload register with all instructions. The preload register acts as a buffer and can be written
immediately after the load of the counter is completed. The enable input enables the count operation. When
the enable signal is set HIGH, the counter will count-up each time a positive clock edge is applied to the clock
input of the counter.
Serial protocols, like UART protocol, need start-bit edge-detection to determine, at the receiver, the start of a
data transmission. When this function is activated, the counter starts counting after the start-bit condition is
detected. The first signal level is sampled into the RXD input data-latch after completing the first timing interval,
which is programmed into the counter. Two latches are used for input and output data (RXD_FF and TXD_FF)
are clocked by the counter after the programmed timing interval has elapsed.
UART
The serial communication is realized by using software and the 8-bit Timer/Counter hardware. The hardware
supports the output of the serial data stream, bit-by-bit, with the timing determined by the counter. The
software/hardware interface connects the mixed signal controller to external devices, systems, or networks.
Timer/Port
The Timer/Port module has two 8-bit counters, an input that triggers one counter, and six 3-state digital outputs.
Both counters have an independent clock-selector for selecting an external signal or one of the internal clocks
(ACLK or MCLK). One of the counters has an extended control capability to halt, count continuously, or gate
the counter by selecting one of two external signals. This gate signal sets the interrupt flag, if an external signal
is selected, and the gate stops the counter.
Both timers can be read from and written to by software. The two 8-bit counters can be cascaded to a 16-bit
counter. A common interrupt vector is implemented. The interrupt flag can be set from three events in the 8-bit
counter mode (gate signal, overflow from the counters) or from two events in the 16-bit counter mode (gate
signal, overflow from the MSB of the cascaded counter).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com