| Electronic Components Datasheet Search |
|
LSN2A Datasheet(PDF) 6 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
LSN2A Datasheet(HTML) 6 Page - Murata Manufacturing Co., Ltd. |
|
6 / 15 page ![]() Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP, 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 6 of 15 Figure 2. Measuring Input Ripple Current Output ripple/noise (also referred to as periodic and random deviations or PARD) may be reduced below specified limits with the installation of additional external output capacitors. Output capacitors function as true filter elements and should be selected for bulk capacitance, low ESR, and appropriate fre- quency response. Any scope measurements of PARD should be made directly at the DC/DC output pins with scope probe ground less than 0.5" in length. All external capacitors should have appropriate voltage ratings and be located as close to the converters as possible. Temperature variations for all relevant parameters should be taken into consideration. Figure 3. Measuring Output Ripple/Noise (PARD) The most effective combination of external I/O capacitors will be a function of your line voltage and source impedance, as well as your particular load and layout conditions. Input Fusing Most applications and or safety agencies require the installation of fuses at the inputs of power conversion components. The LSN2 Series are not internally fused. Therefore, if input fusing is mandatory, either a normal-blow or a slow-blow fuse with a value no greater than twice the maximum input current calculated at low line with the converter's minimum efficiency should be installed within the ungrounded input path to the converter. Safety Considerations LSN2 SIPs are non-isolated DC/DC converters. In general, all DC/DC’s must be installed, including considerations for I/O voltages and spacing/separation requirements, in compliance with relevant safety-agency specifications (usually UL/IEC/EN60950-1). In particular, for a non-isolated converter’s output voltage to meet SELV (safety extra low voltage) requirements, its input must be SELV compliant. If the output needs to be ELV (extra low voltage), the input must be ELV. Input Overvoltage and Reverse-Polarity Protection LSN2 SIP Series DC/DCs do not incorporate either input overvoltage or input reverse-polarity protection. Input voltages in excess of the specified absolute maximum ratings and input polarity reversals of longer than “instantaneous” duration can cause permanent damage to these devices. Start-Up Time The VIN to VOUT Start-Up Time is the interval between the time at which a ramping input voltage crosses the lower limit of the specified input voltage range and the fully loaded output voltage enters and remains within its speci- fied accuracy band. Actual measured times will vary with input source imped- ance, external input capacitance, and the slew rate and final value of the input voltage as it appears to the converter. The On/Off to VOUT Start-Up Time assumes the converter is turned off via the On/Off Control with the nominal input voltage already applied to the converter. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltage enters and remains within its specified accuracy band. See Typical Performance Curves. Remote Sense LSN2 Series offer an output sense function. The sense function enables point-of-use regulation for overcoming moderate IR drops in conductors and/ or cabling. Since these are non-isolated devices whose inputs and outputs usually share the same ground plane, sense is provided only for the +Output. The remote sense line is part of the feedback control loop regulating the DC/ DC converter’s output. The sense line carries very little current and consequent- ly requires a minimal cross-sectional-area conductor. As such, it is not a low- impedance point and must be treated with care in layout and cabling. Sense lines should be run adjacent to signals (preferably ground), and in cable and/or discrete-wiring applications, twisted-pair or similar techniques should be used. The sense function is capable of compensating for voltage drops between the +Output and +Sense pins that do not exceed 10% of VOUT. [VOUT(+) – Common] – [Sense(+) – Common] d 10%VOUT Power derating (output current limiting) is based upon maximum output current and voltage at the converter's output pins. Use of trim and sense functions can cause the output voltage to increase, thereby increasing output power beyond the LSN2's specified rating. Therefore: (VOUT at pins) x (IOUT) d rated output power The internal 10.5 : resistor between +Sense and +Output (see Figure 1) serves to protect the sense function by limiting the output current flowing |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |