DESCRI PTI O N
The TM25 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of
delivering 25 to 28 watts of continuous output
power. They operate at 85 to 264VAC input voltage
without the need of voltage selection. They are
ideally suited for use in medical equipments, safety
systems and monitoring equipments.
FEAT URES
‧ Low safety ground leakage current
‧ 100% burn-in
‧ 85 to 264VAC w i de input range
‧ Input surge current protection
‧ Ov erv o ltage protection
‧ Ov ercurrent protection
‧ Open PCB construction
‧ Compliant w i th RoHS requirements
INPUT SPECIFICAT IONS
Input v o lt age :
85 to 264VAC
Input frequency :
47 to 63 Hz
Input current :
0 . 7 A ( rms ) for 115VAC
0 . 4 A ( rms ) for 230VAC
Earth l eakag e curr ent: 9 0 µA max. @ 115VAC, 60H z
Safety Standard Approvals :
GENERAL SPECIFICATIONS
Switching frequency: 42KHz ±5KHz
Efficiency:
70% minimum on single output
model with Vo
≥ 12V, 68% minimum
on the others
Hold-up time:
10 msec minimum at 110VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
10 amps @ 115VAC or 25 amps
@ 230VAC at 25ºC cold start
Withstand voltage:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
500,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL- HDBK- 217F
EMC Performance (EN60601-1-2:2001)
EN55011:
FCC:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
Radiated immunity, 3V/m for 80~2500 MHz
EN61000-4-4:
Fast transient/burst, ±2KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 3A/m
EN61000-4-11 :
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
ENVIRONMENTA L SPECIFICAT IONS
Operating temperature: 0ºC to +70ºC
S t orage temperature :
-40ºC to +85ºC
Relativ e humidity :
5% to 95% non-condensing
Derating:
Derate from 100% at +50ºC
linearly to 50% at +70ºC
OUTPUT SPECIFICATIONS
Output voltage/current:
See Rating Chart
Total output power:
See Rating Chart
Ripple and noise:
1% peak to peak max.
Overvoltage protection:
Provided on output #1 only;
set at 112-132% of its
nominal output voltage
Overcurrent protection:
All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04%/ºC
maximum
Transient response:
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after a
25% step load change
TÜV EN60601-1
UL 2601-1
CSA C22.2 No. 601.1
TM25 SERIES
(LVD)
RoHS
150µA max. @ 230VAC, 50Hz
TRUMPower
25-28 WATT MEDICAL POWER SUPPLIES
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616
● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com


Similar Part No. - TM25

ManufacturerPart #DatasheetDescription
logo
Schneider Electric
TM251MESC SCHNEIDER-TM251MESC Datasheet
193Kb / 11P
Logic controller, Modicon M251, Ethernet CAN
Apr 6, 2022
TM251MESE SCHNEIDER-TM251MESE Datasheet
177Kb / 8P
controller M251 2x Ethernet
Aug 11, 2019
TM251MESE SCHNEIDER-TM251MESE_V01 Datasheet
187Kb / 10P
Logic controller, Modicon M251, 2x Ethernet
Apr 6, 2022
logo
Sanken electric
TM2541B-L SANKEN-TM2541B-L Datasheet
46Kb / 2P
TO-3PF 25A Triac
TM2541B-L SANKEN-TM2541B-L Datasheet
52Kb / 2P
TO-3PF 25A Triac
More results

Similar Description - TM25

ManufacturerPart #DatasheetDescription
logo
Tumbler Technologies + ...
PM40AL TRUMPOWER-PM40AL Datasheet
211Kb / 2P
40 WATT MEDICAL POWER SUPPLIES
PM65 TRUMPOWER-PM65 Datasheet
220Kb / 2P
65 WATT MEDICAL POWER SUPPLIES
TM41 TRUMPOWER-TM41 Datasheet
223Kb / 2P
30-40 WATT MEDICAL POWER SUPPLIES
TM66 TRUMPOWER-TM66 Datasheet
244Kb / 2P
65 WATT MEDICAL POWER SUPPLIES
TM110 TRUMPOWER-TM110 Datasheet
263Kb / 2P
110 WATT MEDICAL POWER SUPPLIES
TM200 TRUMPOWER-TM200 Datasheet
173Kb / 2P
200 WATT MEDICAL POWER SUPPLIES
TM201 TRUMPOWER-TM201 Datasheet
335Kb / 3P
150- 200 WATT MEDICAL POWER SUPPLIES
TM300 TRUMPOWER-TM300 Datasheet
277Kb / 3P
300 WATT MEDICAL POWER SUPPLIES
TM450 TRUMPOWER-TM450 Datasheet
253Kb / 3P
450 WATT MEDICAL POWER SUPPLIES
TM650 TRUMPOWER-TM650 Datasheet
273Kb / 3P
650 WATT MEDICAL POWER SUPPLIES
More results


Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com