| Electronic Components Datasheet Search |
|
8855 Datasheet(PDF) 9 Page - ASM GmbH |
|
|
|||||||||||||||||||||||||||||
8855 Datasheet(HTML) 9 Page - ASM GmbH |
|
9 / 12 page ![]() 9 VOLTAGE/TEMP UNIT 8954 (Accuracy at 23 ±5˚C (73 ±9˚F) and 30 to 80% relative humidity when zero- adjust is performed after a 60-minute warm-up; accuracy guaranteed for 1 year) Measurement functions Number of channels: 1 voltage or temperature measurement channel Input Voltage input: isolated BNC connector, thermocouple input: Plug-in terminal, Max. rated voltage to earth: 370VAC, DC (withinputisolated from the unit, the maximum voltage that can be applied between input channels and chassis, or across input pins, without causing damage) Voltage measurement range 500μV to 2V/DIV, 12 settings, full-scale = 20DIV, low-pass filter: 1Hz/5Hz/50Hz/500Hz, the measurement resolution: 1/1600 of range (using 16-bitAD) Temperature measurement range 10˚C, 100˚C/DIV, 2 settings, full-scale = 20DIV, low-pass filter: 1Hz/5Hz/50Hz/500Hz, the measurement resolution: 1/1000 of range (using 16-bit AD) Thermocouple range K: -200 to 1350˚C, E: -200 to 800˚C, J: -200 to 1100˚C, T: -200 to 400˚C, N: -200 to 1300˚C, R: 0 to 1700˚C, S: 0 to 1700˚C, B: 300 to 1800˚C, W: 0 to 2000˚C Reference junction compensation: internal/external (interchangeable) Maximum sampling rate Voltage input: 100kS/s, temperature measurement: 4kS/s(dataupdatesevery250μs) Accuracy Voltage input: DC amplitude: ±0.2% f.s. Zero-position: ±0.2% f.s. Temperature measurement (K, E, J, T, N): ±0.1% f.s. ±1°C, ±0.1% f.s. ±2°C (-200°C to 0°C), (R, S, W): ±0.1% f.s. ±3°C, (B): ±0.1% f.s. ±4°C (400 to 1800°C) Reference contact compensation accuracy: ±0.1% f.s. ±1.5°C (for reference junction internal compensation) Frequency characteristics Voltage input: DC to 20kHz +1/-3dB Temperature measurement: DC to 1kHz +1/-3dB Input resistance and capacitance Voltage input: 1MΩ, 60pF (when C is 10kHz) Temperature measurement: 4.8MΩ or more Max. allowable input 30V rms or 60V DC (the maximum voltage that can be applied between input pins without causing damage) F/V UNIT 8955 (Accuracy at 23 ±5˚C (73 ±9˚F) and 30 to 80% relative humidity when zero-adjust is performed after a 30-minute warm-up; accuracy guaranteed for 1 year) Measurement functions Number of channels: 1, Measurements: frequency of voltage input, power frequency, revolution speed, integration, pulse duty comparison, pulse width Input Metal BNC connector, Max. rated voltage to earth: 30V rms or 60V DC (withinputisolatedfromtheunit,themaximumvoltagethatcanbeappliedbetweeninput channels and chassis, or across input pins, without causing damage) Measurement range Frequency: 0.1Hz to 5kHz/DIV between DC to 100kHz, 10 settings Rotations: 10 (r/min) to 500 (r/min)/DIV, 4 settings Power frequency: 50Hz (40 to 60Hz), 60Hz (50 to 70Hz) Integration: 2 kcounts to 1Mcounts/DIV between DC to 90kHz Pulse duty ratio: 100% f.s. between 10Hz to 100kHz, 1 setting Pulse width: 500μs to 100ms/DIV between 2.5μs to 2sec, 6 settings Max. allowable input: 30V rms or 60V DC (themaximumvoltagethatcanbe applied between input pins without causing damage), full-scale = 20DIV, low-pass filter: 5Hz/500Hz/5kHz/100kHz/OFF Measurement resolution Frequency, power frequency, rotations, pulse width, duty ratio: 1/200 of measurement range Pulse duty ratio: 1/2000 of measurement range Response time 10μs + 50ns or less (whenfrequencyislessthan300Hz,measuringintegrationorpulsewidth) 50μs + 50ns or less (whenfrequencyislessthan300Hz,measuringpulsedutyratio,rotation) Accuracy Frequency: ±0.1% f.s. (forsettingsotherthan100kHzf.s.), ±0.7% f.s. (100kHzf.s. setting) Rotation: ±0.1% f.s. Power frequency: ±0.032Hz Pulse duty ratio: ±1% f.s. (10Hzto10kHz), ±4% f.s. (10kHzto100kHz) Pulse width: ±0.1% f.s. Other functions Input pull up resistance: ON/OFF (10kΩ connected to 5V) Threshold level: -10 to +10V variable, slope: rises and drops Level: High, Low, Hold ON/OFF Other functions DIFFERENTIAL PROBE 9322 Power (the POWER CORD 9328 is required for connection) LOGIC PROBE 9320-01/9327 (Accuracyat23±5°C/73±9°F,35to80%rh;accuracyguaranteedfor1year) Function Detection of voltage signal or relay contact signal for High/Low state recording Input 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals), input impedance: 1MΩ (with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to +50V) , pull-up resistance: 2kΩ (contact input: internally pulled up to +5V) Digital input threshold 1.4V/2.5V/4.0V Contact input detection resistance 1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open) and 1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short) Response speed 9320-01 : 500ns or lower, 9327: detectable pulse width 100ns or higher Max. allowable input 0 to +50V DC (the maximum voltage that can be applied across input pins without damage) LOGIC PROBE 9321-01 (Accuracyat23±5°C/73±9°F,35to80%rh;accuracyguaranteedfor1year) Function Detection of AC or DC relay drive signal for High/Low state recording Can also be used for power line interruption detection Input 4 channels (isolated between unit and channels), HIGH/LOW range switching Input impedance: 100kΩ or higher (HIGH range), 30kΩ or higher (LOWrange) Output (H) detection 170 to 250VAC, ±DC (70 to 250V ) (HIGH range) 60 to 150VAC, ±DC (20 to 150V) (LOW range) Output (L) detection 0 to 30VAC, ±DC (0 to 43V) (HIGH range) 0 to 10VAC, ±DC (0 to 15V) (LOW range) Response time Rising edge 1ms max., falling edge 3ms max. (with HIGH range at 200V DC, LOW range at 100V DC) Maximum allowable input voltage 250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage) DIFFERENTIAL PROBE 9322 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) Function For high-voltage floating measurement, power line surge noise detection, RMS rectified output measurement DC mode For waveform monitor output, frequency characteristics: DC to 10MHz (±3dB) , amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3% of full scale (at max. 2000V DC) (full scale: 2000V DC) AC mode For detection of power line surge noise, frequency characteristics: 1kHz to 10MHz ±3dB RMS mode DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz to 100k Hz, response speed: 200ms or less (400VAC), accuracy: ±1% of full scale (DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000VAC) Input Input type: balanced differential input, input impedance/capacitance: H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth: when using grabber clip 1500VAC/DC (CAT II ), 600VAC/DC (CAT III), when using alligator clip: 1000VAC/DC (CAT II), 600VAC/DC (CAT III) Maximum allowable input voltage 2000V DC, 1000VAC (CAT II), 600VAC/DC (CAT III) Output Voltage divider for 1/1000 of input, BNC connectors (outputswitchablefor3modesDC,AC,RMS) Power source Power terminal of the input units, or use with AC ADAPTER 9418-15 (DC 12V) Dimensions and mass: approx. 104.7(4.1 in)W × 28(1.1 in)H × 164.5(6.5 in)D mm approx. 160 g (5.6 oz) Supplied accessories: None Dimensions and mass: approx. 104.7(4.1 in)W × 28(1.1 in)H × 164.5(6.5 in)D mm approx. 150 g (5.3 oz) Supplied accessories: None Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) Note: The unit-side plug of the 9320-01 and 9327 is different from the 9320. Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) Note: The unit-side plug of the 9321-01 is different from the 9321. Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz) WAVE PROCESSOR 9335 Distribution media One CD-R Operating environment Computer equipped with Pentium (133 MHz) or better CPU and at least 32 MB of memory, and running under Windows 95/98/Me or Windows NT 4.0/2000/XP (recommended system: Pentium (200 MHz) or better with at least 64 MB of memory) Display functions Waveform display/X-Y display/digital value display/cursor function/ scroll function/maximum number of channels (32 channels analog, 32 channels logic)/gauge display (time, voltage axes)/graphical display File loading Readable data formats (.MEM, .REC, .RMS, .POW) Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration) Data conversion Conversion to CSV format, tab delimited, space delimited/data culling (simple)/convert for specified channel/batch conversion of multiple files Print functions Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/ hard copy functions usable on any printer supported by operating system Other Parameter calculation/search/clipboard copy/launching of other applications LAN COMMUNICATOR 9333 Distribution media One CD-R Operating environment Computer equipped with Pentium (133 MHz) or better CPU, running under Windows 95/98/Me or Windows NT 4.0/ 2000/Xp operating system, with network adapter installed and configured to use TCP/IP protocol, and at least 64 MB of memory. HiCORDER side Standard LAN connector Communications Ethernet, TCP/IP Remote control Remote control of MEMORY HiCORDER (by sending key codes and receiving images on screen) , print reports, print images from the screen, receive waveform data in same format as waveform files from the MEMORY HiCORDER (binary only) Waveform data acquisition Accept auto-saves from the MEMORY HiCORDER, same format as auto-save files of MEMORY HiCORDER (binary only), print automatically with a MEMORY HiCORDER from a PC. The MEMORY HiCORDER's print key launches printouts on the PC Waveform viewer Simple display of waveform files, conversion to CSV format, Scroll function, enlarge/reduce display, display CH settings. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |