4 / 7 page ![]() TM200 V4.1 11/06 4 MIN / MAX /AVG Display Function In the MIN MAX mode the meter tracks the lowest (MIN), highest (MAX), and average (AVG) readings while displaying elapsed time. 1. Press the MIN MAX button to start the Elapsed Timer (bottom left side of LCD) 2. Begin taking measurements 3. The secondary display (lower right) will display only the primary display’s highest reading (the MAX icon will be visible on the bottom of the LCD). 4. Press the MIN MAX button to see the MIN (minimum) reading. 5. The secondary display (lower right) will display only the primary display’s lowest reading (the MIN icon will be visible on the bottom of the LCD). 6. Press the MIN MAX button to see the AVG (reading) 7. The secondary display (lower right) will display only the primary display’s average reading (the AVG icon will be visible on the bottom of the LCD). 8. Press and hold the MIN MAX button for three (3) seconds to exit this mode and return to normal operation (the MIN, MAX, and AVG display icons should switch off when this mode is successfully exited). 9. Note that in MIN MAX mode, the T1 T2 / T1-T2 button is active allowing the user to view the MIN/MAX/AVG of the T1, T2, or T1-T2 displays. Auto Power OFF (Sleep Mode) The meter will automatically turn off if no keys are pressed during any twenty (20) minute period. To configure the Sleep Mode ON or OFF: 1. With the meter ON, press the SETUP button to enter the SETUP mode (the SETUP display icon will appear on the LCD) 2. Repeatedly press the UP arrow button until the SLP (sleep) icon appears on the LCD 3. Press the ENTER button (on or off will appear on the LCD under the SLP icon) 4. Use the UP/DOWN arrow buttons to select ON (sleep mode on) or OFF (sleep mode defeated) 5. Press ENTER again to save the selection 6. Press SETUP again to exit the setup mode and to return to normal operation. Display OFFSET adjustment Use the display OFFSET feature to compensate for thermocouple irregularities and to better match two thermocouples. The allowable offset range is ± 9 oF (±5oC). 1. With the meter ON, press the SETUP button to enter the SETUP mode (the SETUP display icon will appear on the LCD) 2. Use the UP arrow button to select input T1 or input T2 (icons are shown on left side of LCD) 3. Press the ENTER button; the temperature reading will appear in the primary display area. The offset will be shown in the smaller secondary display area 4. Use the UP/DOWN arrow buttons to program an offset. The available range is ± 9 oF (±5 oC) 5. Press ENTER again to save the selection 6. Press SETUP again to exit the setup mode and to return to normal operation. Turning Power OFF Press the button to turn power off. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |