| Electronic Components Datasheet Search |
|
B40 Datasheet(PDF) 2 Page - RHOPOINT COMPONENTS |
|
|
|||||||||||||||||||||||||||||
B40 Datasheet(HTML) 2 Page - RHOPOINT COMPONENTS |
|
2 / 2 page ![]() 43 RHOPOINT COMPONENTS LTD Email: sales@rhopointcomponents.com Web: www.rhopointcomponents.com B40 4-Channel RF Relays NOTES: 1All parameters specified per EIA/NARM standards for dry reed relays, # RS-421 and RS-436, if a suitable parametric standard exists. 2Unless otherwise noted, all parameters are specified at 25°C and 40% RH. 3Life expectancies based on characteristic life (63.2% failure) calculated from the 2-parameter Weibull distribution. Contact resistance >2.0 Ω defines end of life. 4Frequency at which the difference between output and input signal amplitude exceeds -3dB. (Direct wired using 50 Ω coaxial cable.) 5Maximum increase in operate voltage for any channel when all channel coils are driven at nominal coil voltage and with the same drive polarity. ENVIRONMENTAL RATINGS: Storage Temperature: -35°C to +100°C. Operating Temperature: -20°C to +85°C. Vibration: sinusoidal vibration with an amplitude of 10G over a 10Hz to 2000Hz frequency range shall not cause a closed channel activated at the nominal coil voltage to open, not an open channel to close. Max Soldering Temperature: 226°C (438°F) max for 1 minute dwell time. Temperature measured at a relay ball termination. B40 Test Parameters Conditions 1,2 Min Typ Max Units Coil Resistance 49.5 55.0 60.5 Ω Nominal Voltage 3.3V Coil 3.3 4.0 Volts DC Must Operate Voltage 2.4 Volts DC Must Release Voltage B40-0002 0.4 Volts DC Coil Resistance 149.4 166.0 182.6 Ω Nominal Voltage 5V Coil 5.0 6.0 Volts DC Must Operate Voltage 3.8 Volts DC Must Release Voltage B40-0003 0.4 Volts DC Switching Voltage Max DC/Peak AC 125 Volts Switching Current 0.25 Amps Carry Current (Continuous) Switch and Shield 0.5 Amps Contact Rating (Resistive Load) Resistive Load 3.0 Watts Life Expectancy Signal Switching 3 1VDC / 10mA 1000 x 10 6 Ops Resistive Load 3 12VDC / 10mA 1 x 10 6 Ops Other Load Conditions 3 Consult Factory Static Contact Resistance (initial) 0.05VDC / 10mA 0.125 Ω Dynamic Contact Resistance (initial) 0.5V / 50mA 100 Hz, 1.5 mSec 0.150 Ω Insulation Res All Isolated Pins 100VDC 10! 10 10 12 Ω Capacitance Across Contacts Shield Guarding 0.2 pF Capacitance Open Contact to Coil Shield Guarding 0.3 pF Capacitance Closed Contact to Coil Shield Guarding 0.5 pF Operate Time (including bounce) Nominal Voltage coil drive @ 30 Hz, 100 200 µSec Release Time (Si diode damped) square wave 30 50 µSec RF Insertion Loss 4 -3 dB roll-off frequency 11.0 GHz Signal Rise Time (10% - 90%) Corrected for measurement 40 pSec system response time Magnetic Interaction 5 Between Adjacent Channels 16 % V (DC/Pk AC) V (DC/Pk AC) V (DC/Pk AC) Across Contacts Contact to Coil Contact To Shield Dielectric Strength 100 µA 100 µA 100 µA 150 1000 1000 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |