Back Button F25S004A Datasheet HTML 5Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 6Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 7Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 8Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 9Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 10Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 11Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 12Page - Elite Semiconductor Memory Technology Inc. F25S004A Datasheet HTML 13Page - Elite Semiconductor Memory Technology Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 33 page
background image
ESMT
F25S004A
Elite Semiconductor Memory Technology Inc.
Publication Date: Jan. 2009
Revision: 1.1
9/33
Instructions
Instructions are used to Read, Write (Erase and Program), and
configure the device. The instruction bus cycles are 8 bits each
for commands (Op Code), data, and addresses. Prior to
executing any Byte-Program, Auto Address Increment (AAI)
programming,
Sector-Erase,
Block-Erase,
or
Chip-Erase
instructions, the Write-Enable (WREN) instruction must be
executed first. The complete list of the instructions is provided in
Table 5. All instructions are synchronized off a high to low
transition of CE . Inputs will be accepted on the rising edge of
SCK starting with the most significant bit. CE must be driven
low before an instruction is entered and must be driven high after
the last bit of the instruction has been shifted in (except for Read,
Read-ID and Read-Status-Register instructions). Any low to high
transition on CE , before receiving the last bit of an instruction
bus cycle, will terminate the instruction in progress and return the
device to the standby mode.
Instruction commands (Op Code), addresses, and data are all
input from the most significant bit (MSB) first
TABLE 5: DEVICE OPERATION INSTRUCTIONS
Bus Cycle
1
2
3
4
5
6
Cycle Type/
Operation
1,2
Max
Freq
SIN
SOUT
SIN
SOUT
SIN
SOUT
SIN
SOUT SIN
SOUT SIN SOUT
Read
33 MHz
03H
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z
X
DOUT
High-Speed-Read
0BH
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z
X
X
X DOUT
Sector-Erase
4,5 (4K Byte)
20H
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z
-
-
-
-
Block-Erase
5 (64K Byte)
D8H
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z
-
-
-
-
Chip-Erase
5
60H
C7H
Hi-Z
-
-
-
-
-
-
-
-
-
-
Byte-Program
5
02H
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z DIN Hi-Z
-
-
Auto-Address-Increment-word
programming (AAI)
6
ADH
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z DIN0 Hi-Z DIN1 Hi-Z
Read-Status-Register
(RDSR)
05H
Hi-Z
X
DOUT
-
Note
7
-
Note
7
-
Note
7
--
Enable-Write-Status-Register
(EWSR)
8
50H
Hi-Z
-
-
-
-
-
-
-
-
-
-
Write-Status-Register
(WRSR)
8
01H
Hi-Z
Data
Hi-Z
-
-
-.
-
-
-
-
-
Write-Enable (WREN)
11
06H
Hi-Z
-
-
-
-
-
-
-
-
-
-
Write-Disable (WRDI)
04H
Hi-Z
-
-
-
-
-
-
-
-
-
-
Read-Electronic-Signature
9
(RES)
ABH
Hi-Z
X
12H
-
-
-
-
-
-
-
-
Jedec-Read-ID (JEDEC-ID)
10
9FH
Hi-Z
X
8CH
X
20H
X
13H
-
-
-
-
90H (A0=0)
8CH
12H
Read-ID (RDID)
90H (A0=1)
Hi-Z A23-A16 Hi-Z A15-A8
Hi-Z
A7-A0 Hi-Z
X
12H
X
8CH
Enable SO to output RY/BY#
Status during AAI (EBSY)
70H
Hi-Z
-
-
-
-
-
-
-
-
Disable SO to output RY/BY#
Status during AAI (DBSY)
50MHz
80H
Hi-Z
-
-
-
-
-
-
-
-
1.
Operation: SIN = Serial In, SOUT = Serial Out
2.
X = Dummy Input Cycles (VIL or VIH); - = Non-Applicable Cycles (Cycles are not necessary)
3.
One bus cycle is eight clock periods.
4.
Sector addresses: use AMS-A12, remaining addresses can be VIL or VIH
5.
Prior to any Byte-Program, Sector-Erase, Block-Erase,or Chip-Erase operation, the Write-Enable (WREN) instruction must be
executed.
6.
To continue programming to the next sequential address location, enter the 8-bit command, ADH, followed by the data to be
programmed.
7.
The Read-Status-Register is continuous with ongoing clock cycles until terminated by a low to high transition on CE .
8.
The Enable-Write-Status-Register (EWSR) instruction and the Write-Status-Register (WRSR) instruction must work in conjunction
of each other. The WRSR instruction must be executed immediately (very next bus cycle) after the EWSR instruction to make both
instructions effective.
9.
The Read-Electronic-Signature is continuous with on going clock cycles until terminated by a low to high transition on CE .
10. The Jedec-Read-ID is output first byte 8CH as manufacture ID; second byte 20H as top memory type; third byte 13H as memory



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com